EA-304非对称换热器管板应力分析计算 被引量:2

Stress Analysis Calculation of Tube-sheet for EA-304 Heat Exchanger
下载PDF
导出
摘要 介绍了一端管板与管箱和壳体焊接的固定结构、另一端管板可滑动的非对称换热器在压力和温差载荷作用下的分析计算方法,分析计算了原进口、第一、第二次国产化3台换热器管板应力,管板厚度由117mm减薄为50mm,换热器的各项性能均超过原进口设备。 This paper introduced an analytical calculating method of stresses caused by pressure and thermal difference for an asymmetric tubesheet of heat exchanger which was fixed at one end and sliding at the other, analyzed and calculated the sheet stresses for three heat exchangers. The results indicated that the thickness of sheet was reduced from 117 mm to 50 mm and performance of the heat exchanger was superior to the imported equipment.
出处 《压力容器》 北大核心 2009年第4期10-14,46,共6页 Pressure Vessel Technology
关键词 固定管板 滑动管板 管板布管区 周边不布管区 管板上下表面温差 对称载荷分析弹性基础板 反对称载荷分析削弱圆板 fixed sheet sliding sheet tube area tube - free area thermal difference between upper and lower surface analysis of symmetrical load elastical baseplate analysis of the asymmetric load weakeneddisk