摘要 简述了医疗器械的电磁兼容性设计的意义和重要性,分析了医疗监护仪产生电磁干扰的原因、传输途径以及基于s3c2410嵌入式系统的电磁干扰的特殊性。以基于s3c2410的医疗监护仪为实例介绍了嵌入式应用系统的电磁兼容性设计的一般方法,兼顾了软件和硬件的抗干扰设计以保证系统的稳定。 A brief summary was given about significance and importance of medical devices EMC design, and the cause in generating electromagnetic disturbance and the route on transmission of medical monitoring instruments were analyzed, with the embedded system's electromagnetic interference particularities based on the s3c2410 analyzed as well. The general method of embedded application system's electromagnetic compatibility design was described by means of taking the s3c2410 medical monitoring instrument as the example. Its guarantee system's stability was also covered and ensured in the software and hardware's anti-interference design.
出处 《辽宁工业大学学报(自然科学版)》 2009年第2期80-82,共3页 Journal of Liaoning University of Technology(Natural Science Edition)
关键词 电磁兼容 监护仪 S3C2410 EMC medical monitor s3c2410
  • 相关文献

参考文献3

  • 1殷和国,杨银堂,付俊兴,李雯.芯片级电磁兼容性的设计[J].现代电子技术,2004,27(3):52-55. 被引量:2
  • 2沈小宇.电磁兼容学科综述[C]//电气技术发展综述.北京:中国电工技术学会电磁兼容专委会,2004:73-76.
  • 3Goldberg G.General features for development of EMC product standards[J].IEC Seminar on EMC product standards,1995(4):3-4.

二级参考文献11

  • 1[1]IEC 61967-1.Integrated circuits-Measurement of electromagnetic emissions, 150 kHz to 1 GHz-Part 1: General conditions and definitions.47A/632/FDIS.2001.
  • 2[2]IEC 61967-2.Integrated circuits-Measurement of electromagnetic emissions, 150 kHz to 1 GHz-Part 2:Mesurement of radiated emissions,TEMcell method(150 kHz to 8 GHz)[J].47A/619/NP,New Work Item Proposal,Date of proposal:Jul.2001.
  • 3[3]IEC 61967-3.Integrated circuits-Measurement of electromagnetic emissions, 150 kHz to 1 GHz-Part 3: Measurement of radiated emissions, surface scan method (10 kHz to 3 GHz)[J].47A/620/NP, New Work Item Proposal, Date of proposal: Jul. 2001.
  • 4[4]IEC 61967-4.Integrated circuits-Measurement of electromagnetic emissions, 150 kHz to 1 GHz-Part 4:Measurement of conducted emissions -1/150 direct coupling method.47A/636/FDIS, Final Draft International Standard, Distributed on 2002.
  • 5[5]Tzong-Lin Wu,et al. A novel systematic approach for equivalent model extraction of embedded high-speed interconnects in time domain[J].IEEE Trans. on Electromagnetic Compatibility, 2003,45(3).
  • 6[6]Martin P.Robinson,et al. A simple model of EMI-Induced timing jitter in digital circuits, its statistical distribution and its effect on circuit performance[J].IEEE Trans. on Electromagnetic Compatibility, 2003,45(3).
  • 7[7]Charles F. Bunting. Shielding effectiveness in a two-dimensional reverberation chamber using finite-element techniques[J].IEEE Trans. on Electromagnetic Compatibility, 2003,45(3).
  • 8[8]Kimitoshi Murano.A new immunity testmethod[J].IEEE Trans.on Electromagnetic Compatibility, 2002,44(1).
  • 9[9]Xiaoning Ye,et al. High-performance inter-PCB connectors:analysis of EMI charac-teristics[J].IEEE Tans.on Electromagnetic Compatibility, 2002,44(1).
  • 10[10]Christos Christopoulos,James L Drewniak.Foreword advanced EMC numerical modeling[J]. IEEE Tans.on Electromagnetic Compatibility, 2003,45(2).

共引文献1

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部