摘要 提出一种利用负电晕放电原理检测SF6气体泄漏的设计方案,综合应用低功耗微控制器和外围芯片设计硬件电路,其中传感电路采用冗余技术,解决了传统的零漂并误报警的问题。系统采用光耦隔离技术有效地消除了干扰并抑制了噪声,电极采用新型敏感材料和独特的结构方式,解决了传统SF6气体检漏仪不能在线监测的难题。仪表性能稳定、灵敏度高、使用寿命长,可广泛应用于SF6气体泄漏的便携或在线测量,测量范围为0—5000ppm(1ppm=10^-6),灵敏度0.1ppm. A scheme for SF6 gas leak-detector with negative corona discharge principle was designed. The hardware circuit mainly consisted of low-power components, in which sensing circuits with hardware redundant technology resolved the traditional problems of zero-point drift and false alarm. The system with light-coupled isolation technology eliminated disturb and restrained yawp effectively, and resolved the traditional technology problem of monitoring on line because measuring probe used the new material and special frame. The system is stable, high sensitive and long-life, which can be widely used to detect SF6 gas "as portable or on-line instrument. Its measuring range is from 0 to 5000 ppm ( 1 ppm = 10 -6 ), the sensitivity is 0.1 ppm.
出处 《仪表技术与传感器》 CSCD 北大核心 2009年第4期138-139,142,共3页 Instrument Technique and Sensor
关键词 SF6气体 负电晕 检漏 灵敏度 SF6 gas negative corona leak hunting sensitivity
  • 相关文献

参考文献5

二级参考文献5

  • 1胡大可.MSP430系列FLASH型超低功耗16位单片机[M].北京:北京航空航天大学出版社,2002.11.
  • 2Analog Devices.3 V/5 V,450 mA 16 - Bit,Sigma-Delta ADC AD7715,2000.
  • 3Texas Instraments Incorporated. MAX3221 3 - V to 5.5 - V multichannel RS - 232 line driver/receiver,2000.
  • 4提高485总线的可靠性[DB/0L](2003—12—13)[2004—10—15].http://www.cetinet.com/t-article/list.asp?indexid=1777.
  • 5谢军.工控组态软件的功能分析和应用[J].交通与计算机,2000,18(3):46-48. 被引量:15

共引文献59

同被引文献63

引证文献8

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部