期刊文献+

氢氯化反应器的失效分析及改进 被引量:1

Analysis on failures of hydrochloride reactor and techniques to avoid them
下载PDF
导出
摘要 由于生产负荷增加,导致四川鸿鹤精细化工有限责任公司氢氯化反应器酸腐蚀失效,介绍了该设备失效形态,分析认为该设备失效原因主要有:原料气特性的改变,气体分布器能力不足,设备本身设计制作质量的欠缺,提出了相应的改进措施。经改进后,设备运行稳定,且能满足生产负荷需求。 With the increase of production load, the hydrochloride reactor is acid-corrosion destroyed in Sichuan Honghe Fine-chemical Company Ltd.. The inactivation shape of the hydrochloride reactor is introduced. Failure cause analysis of the hydrochloride reactor are as the followings: characteristic change of feed gas, iusutticient ability of gas distributor and equipment defect of production quality, the corresponding improvement measures are put forward. After the improvement, stable operation of the equipment is ensured and the production load can meet the requirement.
作者 罗俊勇
出处 《现代化工》 CAS CSCD 北大核心 2009年第5期65-67,69,共4页 Modern Chemical Industry
关键词 氢氯化反应器 失效分析 改进 酸腐蚀 管-板连接 hydrochloride reactor failure analysis improvement acid corrosion tube-plate connection
  • 相关文献

参考文献4

  • 1初世宪,王洪仁编著.工程防腐蚀指南[M].北京:化学工业出版社,2006.
  • 2化工设备设计全书编辑委员会.废热锅炉[M].北京:化学工业出版社,2002.
  • 3国家医药管理局上海医药设计院.化工工艺设计手册[M].北京:化学工业出版社,1996..
  • 4国家质量技术监督局.GB151-1999管壳式换热器[S].北京:中国标准出版社,1999.

共引文献17

同被引文献4

引证文献1

二级引证文献2