期刊文献+

硼氢化钠-氢还原重量法测定难溶解钌-硼焊料中的钌 被引量:7

Gravimetry for the Determination of Ru in Difficultly Dissolved Ru-B Solder Using NaBH_4-H_2 Reduction
下载PDF
导出
摘要 建立了硼氢化钠-氢还原重量法测定难溶解钌-硼焊料中高量钌的方法,研究了测定钌的条件,比较了试样的玻璃封管酸溶解法与碱熔融法和钌的硼氢化钠-氢还原重量法与蒸馏-硫脲显色分光光度法。结果表明:玻璃封管酸溶解法较碱熔融法费时且操作繁琐,但钌的测定体系单纯;硼氢化钠-氢还原重量法较蒸馏-硫脲显色分光光法费时,但因钌的测定浓度较高,故相对误差较小。测定50~100mg钌,相对误差-0.24%~+0.25%。方法准确度高,选择性好,实用性强,已用于钌-硼焊料中质量分数>90%钌的测定,结果满意。 A new method for gravimetry of high content Ru in difficultly dissolved Ru - B solder using NaBH4 - H2 reduction was established. The conditions were studied, systematically. The acerbity decomposition method of glass -envelop- tube for sample was compared with alkali fusing method, and at the same time, the gravimetry of NaBHg - H2 reduction for Ru was compared with distillation - thiourea color spectrophotometry. The results showed that the acerbity decomposition method of glass - envelop - tube was time -comsuming and its operation was much complex than the alkali fusing method, but the system of gravimetry was simple. The gravimetry of NaBH4 - H2 reduction was time - comsuming than the distil- lation - thiourea color spectrophotometry, but because of high determining concentration of Ru, its relative error was less. For the determination of 50 mg - 100 mg of Ru, relative error was -0.24% - +0.25%. The proposed method has high accuracy, good selectivity and better applicability, and it has been applied to determine Ru in Ru - B solder with satisfactory results.
出处 《贵金属》 CAS CSCD 北大核心 2009年第2期41-45,共5页 Precious Metals
基金 国防科工委基金项目(JPPT-115-122) 昆明贵金属研究所研究与开发基金(JS-06-RD03)项目资助
关键词 分析化学 硼氢化钠-氢还原重量法 钌-硼焊料 analytical chemistry gravimetry using NaBH4 -H2 reduction Ru- B solder Ru
  • 相关文献

参考文献8

二级参考文献24

  • 1曹喜焕.硼粉中总硼含量的测定[J].推进技术,1996,17(5):80-83. 被引量:9
  • 2朱武勋.原子吸收光谱法测定三氯化钌中Ru含量[J].分析试验室,2004,23(增刊12):237-238.
  • 3昆明贵金属研究所,GB1486-1979 铂-钌合金化学分析方法,1979年
  • 4杨红霞 李冰.硼的测定方法.化学通报,2005,68(6):1-4.
  • 5余建明.贵金属分离与精炼工艺学[M].北京:化学工业出版社,2006:30-37.
  • 6Shekhar R, Arunachalam J, Radha Krishna G, et al. Determination of boron in Zr - Nb alloys by glow discharge quadrpole mass spectrophotometry[ J]. J Nucl Mater, 2005, 340 : 284 - 290.
  • 7Yamane T, Kouzaka Y, Hirakawa M, et al. Continuous flow system for the determination of trace boron in iron and steel utilizing in - line preconcentration/separation by sephadex column coupled with fluorimetric detection [ J ]. Talanta, 2001,55- 387 -393.
  • 8Cocdo A G, Dorado M T, Padilla I. Evaluation of different sample introduction approaches for the determination of boron in unalloyce steels by inductively coupled plasma mass spectrometry [ J ]. Spectrochim Acta, Part B, 2005,60 : 73 - 79.
  • 9Bemard M, Deneuville A, Muret P. Non - destructive determination of boron concentration of heavily doped metallic diamond thin films from Raman spectroscopy[ J]. Diamond Relat Mater, 2004,13 : 282 - 286.
  • 10Shen J - S, You C - F. A 10 - fold improvement in the precision of boron isotopic analysis by negative thermal ionization mass spectrometry [ J ]. Anal Chem, 2003,75 : 1972 - 1977.

共引文献22

同被引文献123

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;