摘要
介绍了采用预处理+厌氧水解+SBR工艺处理农药废水的方法,设计处理规模200 m3/d。实践证明,通过该工艺处理后,出水水质达到《污水综合排放标准》(GB8978—1996)一级标准。
The treatment methods of pesticide wastewater with "pretreatment+ hydrolysis+ SBR" process are introduced. The design treatment capacity is 200 m^3/d. The result shows that the wastewater can reach the integrated wastewater discharge standard (GB8979- 1996) after the treatment.
出处
《化学工业与工程技术》
CAS
2009年第2期55-57,共3页
Journal of Chemical Industry & Engineering
关键词
预处理
农药废水
厌氧水解
SBR
Pretreatment
Pesticide wastewater
Hydrolysis
SBR