浅析了上置式与下置式隔膜式气压罐的工作特点与差异,结合适应消防要求的不锈钢多级离心泵应用技术,提出了自喷灭火稳压系统选用设计改进的点滴经验,可供建筑消防给水系统设计和审查人员参考。
The working characters and differences between the above top floor and underground position of diaphragm pneumatic vessel are analyzed. Combined with the application technology of stainless steel multi-stage centrifugal pump which meets the fire requirement, some experiences on the choice and design improvement of sprinkler stable pressure system are put forward, which can be used as reference for design and review of building fire water supply system.