期刊文献+

介绍细胞过孔分析仪 被引量:3

AN INTRODUCTION TO THE CELL TRANSIT ANALYSER
下载PDF
导出
摘要 细胞过孔分析仪(CTA)是一种国外新发明的血液流变学仪器,不仅能在很短时间内测量出大量红细胞通过膜孔的平均时间,还能给出这些细胞过孔时间的分布。本文简介这一仪器的工作原理和主要性能. The Cell Transit Analyser (CTA) is a newly invented instrument, which can not only measure the average time for a large number of red blood cells through micropores but also give distribution of the transit time. This paper will briefly review its operational principle and basic performances.
作者 严宗毅
出处 《中国血液流变学杂志》 CAS 1998年第1期26-32,共7页 Chinese Journal of Hemorheology
基金 国家自然科学基金资助项目
关键词 红细胞变形性 血液流变学 细胞过孔分析仪 RBC deformability micropore filter hemorheology The Cell Transit Analyser (CAT)
  • 相关文献

参考文献2

二级参考文献17

  • 1严宗毅,董立奇,钱民全,翁维良,王怡.用核孔滤膜在等负压条件下研究红细胞变形能力的理论分析[J].中国生物医学工程学报,1989,8(2):86-95. 被引量:10
  • 2孙瑞娟,Proceedings of Beijing Satellite Symposium of the Eightg International Congress of Biorheology,1992年
  • 3Lucas G S,Caldwell N M,Meakin M and Stuart J.Comparison of Initial-flow-rate andPositive - pressure Filtration Methods for the Study of Erythrocyte Deformability. Clinical Hemorheology . 1983
  • 4Nakamura T,Ikawa T,Shio H and Uyesaka N.RBC Filterability as Measured with A NewlyDesigned Nickel Mesh Filter with 3μPores. Biorheology . 1991
  • 5Moessmer G and Meiselmen H J.A New Micropore Filtration Approach to the Analysisof White Cell Rheology. Biorheology . 1990
  • 6Chien S,Schmalzer E A,Lee MML.Impelluso T and Skalak R.Role of White Blood Cellsin Flltration of Blood Cell Suspensions. Biorheology . 1983
  • 7Anegawa T,Shio H,Yasuda Y,Fujimoto N and Kameyama M.Erytrhrocyte Deformabilityas Measured with A Newly Developed Nickel Mesh. Clinical Hemorheology . 1987
  • 8Matrai A,Bogar L,Flute P T and Dormandy J A.Comparison of Four Blood Filtration Tech-niques. Clinical Hemorheology . 1984
  • 9Schmalzer E A,Skalak R,Usami S,Vayo M and Chien S.Influence of Red Cell Concentra-tion on Filtration of Blood Cell Suspensions. Biorheology . 1983
  • 10Skalak R,Impelluso T,Schmalzer E A and Chien S.Theoretical Modeling of Filtration ofBlood Cel1 Suspensions. Biorheology . 1983

共引文献7

同被引文献35

  • 1严宗毅,董立奇,钱民全,翁维良,王怡.用核孔滤膜在等负压条件下研究红细胞变形能力的理论分析[J].中国生物医学工程学报,1989,8(2):86-95. 被引量:10
  • 2Yuji Kikuchi,Kazuo Sato,Yoshinori Mizugushi. Modified Cell-Flow Microchannels in Single-Crystal Silicon Substrate and Flow Behav ior of BloodCells. Microvascular Research,1994,47:222
  • 3Yuji Kikuchi. Effect of Leukocytes and Platelets on Blood Flow througe a Paralle Array of Microchannels. Microvascular Research,1995,50:288
  • 4Sutton N,Tracey MC,Johnston ID,et al.A Noval Instrument for Studying the Flow Behavior of Erythrocytes through Microchannels Simulating Human Blood Capillaries. Microvascular Research, 1997,53:272
  • 5Jones JG,AdmasRA,Evans SA.Bulk filtration through micropore membrane for anslysis blood cell rheology inClinical research.Clin Hemorheol,1994,14:149-169.
  • 6Chien S,Dormandy J,Emst E et al.Clinical Hemorheology.Dordrecht:MartinersNijhoff,1987,42-49.
  • 7Bull BS,Chien S,Dormandy JA et al.Guidelines for measurement of blood viscosity anderythrocyte deformability.Clin Hemorheol,1986;6:636-453.
  • 8Staubli M,Stone PCW,Straub PW et al.Evaluation of methods for measuring erythrocytedeformability.Clin Hemorheol,1986,6:589-602.
  • 9Stone PCW.Caswell M,Nash GB et al.Relative efficacy of filtrometers used to measureerythrocyte deformability.Clin Hemorheol,1990,10:275-286.
  • 10Neumann FJ,Haput H,Zimmermann R et al.The use of metal microsieves in red bloodcell filtration.Clin Hemorheol,1989,9:125-137.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部