论述了电流互感器误差产生的机理、影响误差的因素,介绍了断电保护应用所允许误差10%误差曲线,提出了电流互感器实际误差及二次允许负载阻抗的计算方法、计算步骤,并举例说明。在电力系统中可依据实际情况来计算和选择电流互感器二次负载的允许值。
The mechanisms to produce error in current transformer and the factor to influence error have been elaborated. 10% error curve of permissible error in the application of relay is introduced. The calculation method and procedure of actual error in current transformer & secondary permissible load impedance are put forward with example. The permissible value of secondary load in current transformer can be calculated and selected as per real condition in power system.
出处
《陕西电力》
2009年第4期47-50,共4页
Shanxi Electric Power
关键词
电流互感器
误差
允许负载
计算
current transformer
error
permissible load
calculation