摘要
在神光Ⅲ原型装置上,利用八束三倍频激光注入金柱腔靶,开展了光学高温计与软X射线能谱仪测量辐射温度的比对研究;利用功率平衡关系式,分析了神光Ⅲ原型1ns内爆标准腔、1ns输运腔的辐射温度与激光功率的关系,得到了两种腔靶X射线转换效率(耦合效率)约为50%—55%.
Experimental measurement of radiation temperature by a streaked optical pyrometer and a soft X-ray spectrometer viewing through the laser entrance hole are performed on SG- Ⅲ prototype laser facility. It was found that the two methods compares well. Using the power balance relation,the laser-hohlraum coupling efficiency for 41.0 mm × 1.7 mm hohlraum and 41.0 mm × 2.1 mm hohlraum is around 50%-55 % .
出处
《物理学报》
SCIE
EI
CAS
CSCD
北大核心
2009年第5期3255-3261,共7页
Acta Physica Sinica
基金
国家重点基础研究发展计划(批准号:2007CB814802)资助的课题~~
关键词
辐射温度
冲击波
黑腔靶
激光靶耦合效率
radiation temperature, shock wave, hohlraum, laser-hohlraum coupling efficiency