摘要
文章通过晋东南1000kV主变现场调试的实践,对1000kV主变本体、调压和补偿的原理进行了探讨,对试验过程中主变调压、变比试验、高压套管试验、绕组连同套管的直流电阻试验、绝缘油颗粒含量检测等项目进行了重点简述和总结,可为特高压变压器现场试验工作提供参考。
Through the on-site commissioning of main transformer in Southeast Shanxi Substation, the principles of 1000 kV main transformer body, voltage regulation and compensation are researched. The test items such as voltage regulation and transformation ratio test of main transformer, high voltage bushing test, DC resistance test of transformer windings and bashings, the detection of insulating oil gas granule content and so on are summarized in the hope of providing reference for on-site tests of UHV main transformers.
出处
《电网技术》
EI
CSCD
北大核心
2009年第10期11-15,共5页
Power System Technology
关键词
1000
KV变压器
现场交接试验
主变调压
直流电阻
绝缘油颗粒含量
1000 kV transformer voltage regulation
DC resistance granule content on-site handover test
test
insulating oil gas