MRI无创测温技术在高强度聚焦超声损伤活体羊肝组织中的应用 被引量:1

Application of Non-invasive Temperature-measured Technique using MRI in Monitoring High Intensity Focused Ultrasound Radiation Argali′s Livers In Vivo
下载PDF
导出
摘要 目的磁共振成像(MRI)无创测温技术实时监测高强度聚焦超声(HIFU)辐照活体羊肝组织的靶区温度,观察靶区温度的分布特点。方法MRI导航高强度聚焦超声治疗系统(MRIgHIFU)定点连续辐照羊肝组织,GRE-T-MAP序列实时监测靶区温度并采集3s,6s,10s的温度图。结果GRE-T-MAP每3~4s采集一幅以不同颜色标示的温度图像:同一层面,靶区中心温度最高,周围依次降低;焦点层面的平均温度比其前、后层面高。靶区温度随辐照时间延长而增高,辐照10s时焦点层面平均温度(63.03±5.39)℃,最高温度(76.19±2.98)℃。结论GRE-T-MAP序列能准确获取靶区及其周围的温度范围,MRI测温技术可用于评价HIFU辐照活体动物肝脏的效果,为进一步研究磁共振导航高强度聚焦超声治疗系统的临床应用奠定基础。 Objective To monitor real-time temperature of Argali's livers in vivo under high intensity focused ultrasound (HIFU) radiation and to observe temperature distribution of target area using magnetic resonance imaging (MRI). Methods Normal livers were under uninterrupted radiation by HIFU while dynamic temperature images were captured by GRE-T-MAP and images of radiation for 3 s,6 s,and 10 s were analyzed. Results GRE-T-MAP captured images of target temperatures labeled with different colors every 3-4 s. 31ae images showed that central temperature was much higher than that of the peripheral area in the same deck and that of the pre-and post deck. Target temperature was increasec with the prolongation of radiation time. The average temperature was (63.03±5.39) ℃ and the highest was (76.19±2.98)℃ at 10 s. Conclusion GRE-T-MAP can capture the temperature range of target and peripheral area accurately,therefore it can be used to evaluate the effects of HIFU in radiating livers with living animals and provide evidences for further study of MRIgHIFU in chnic.
出处 《中国医科大学学报》 CAS CSCD 北大核心 2009年第3期184-185,188,共3页 Journal of China Medical University
基金 国家“十一五”科技支撑计划基金资助项目(2006BAI03A02)
关键词 磁共振成像 高强度聚焦超声 无创测温 magnetic resonance imaging high intensity focused ultrasound non-invasive temperature-measured technique
  • 相关文献

参考文献7

  • 1Chiristakis DM,Pavlou O,Velev K,et al.High intensity focused ultrasound ablation of kidney guided by MR1 [ J ].Ultrasound Med Biol, 2004,30( 3 ) : 397-404.
  • 2Bohris C, Schreiber WG, Jenne J, et al. Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy [J]. Magn Resou Imaging, 1999,17 (4) : 603-610.
  • 3Graham S J, Chen L, Leitch M, et al. Quantifying tissue damage due to focused ultrasound heating observed by MRI [J]. Magn Reson Med, 1999,41(2) :321-328.
  • 4Madio DP,Van Gelderen P,DesPres D,et al. On the feasibility of MRI-guided focused ultrasound for local induction of gene expression [J]. Magn Reson Imaging, 1998,8( 1 ) : 101-104.
  • 5Chen L,Bouley D,Yuh E,et al. Study of focused ultrasound tissue damage using MRI and histology [J]. Magn Reson Imaging, 1999,10 (2): 146-153.
  • 6董洁,熊正爱,王智彪,张炼,刘映江,胡晓.磁共振成像实时监控高强度聚焦超声热消融羊肌肉组织的可行性研究[J].重庆医科大学学报,2008,33(9):1099-1102. 被引量:3
  • 7贺雪梅,熊欣,邹建中,李发琪,马平,王智彪.高强度聚焦超声辐照靶区回声强度与温度的相关性实验研究[J].临床超声医学杂志,2008,10(4):217-219. 被引量:12

二级参考文献11

  • 1邹建中.HIFU高强度聚焦超声治疗肿瘤的超声定位、实时监控及疗效评价[J].临床超声医学杂志,2001,3(S1):23-29. 被引量:15
  • 2Cohen ZR,Zaubermann J,Harnof S,et al. Magnetic resonance imaging-guided focused ultrasound for thermal ablation in the brain: a feasibility study in a swine model[J]. Neurosurgery,2007;60(4):593-600.
  • 3Ram Z,Cohen ZR,Harnof S,et al. Magnetic resonance imaging-guided,high-intensity focused ultrasound for brain tumor therapy [J]. Neurosurgery, 2006; 59 (5) : 949-956.
  • 4Gomy KR,Hanqiandreou NJ,Hesley GK,et al.MR guided focused ultrasound:technical acceptance measures for a clinical system [J]. Phys Med Biol,2006;51(12):3155-3173.
  • 5Quesson B,de Zwart JA,Moonen CT.Magnetic resonance temperature imaging for guidance of thermotherapy[J]. Magn Reson Imaging, 2000; 12(4) : 525-533.
  • 6Rabinovici J,Inbar Y,Revel A,et al.Clinical improvement and shrinkage of uterine fibroids after thermal ablation by magnetic resonance-guided focused ultrasound surgery[J]. Ultrasound Obstet Gynecol, 2007; 30 ( 5 ) : 771-777.
  • 7Stewart EA,Gostout B,Rabinovici J,et al.Sustelned relief of leiomyoma symptoms by using focused ultrasound surgery[J]. Obstet Gynecol, 2007; 110(2 pt 1 ) : 279-287.
  • 8Gedroyc WM,Anstee A.MR-guided focused ultrasound[J]. Expert Rev Med Devices,2007;4(4):539-547.
  • 9Pauly KB, Diedefich CJ,Rieke V,et al. Magnetic nance-guided high-intensity ultrasound ablation of the prostate[J]. Top Magn Reson Imaging,2006; 17(3): 195-207.
  • 10Gedroyc WM.New clinical applications of Magnetic reso-nance-guided focused uhrasound[J]. Top Magn Reson Imaging,2006; 17(3 ) : 189-194.

共引文献13

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部