摘要 介绍了一台300 MW机组经过汽封改造后,启动过程中产生异常振动的情况。通过对机组开机全过程的振动监测,对振动数据分析研究,确诊了振动故障的原因,经过对高中压转子返厂精确动平衡及汽封间隙调整处理,使机组顺利投运。 The abnormal vibration fault during start-up process of a 300MW turbine generator unit after honeycomb seal transformation is introduced in detail. The causes are diagnosed by detecting the vibration in the whole initiating process of the unit and analyzing the vibration data. The unit is running smoothly after returning to plant for accurate dynamic balance and adjusting the gap of honeycomb seal on high- medium pressure rotor.
出处 《江苏电机工程》 2009年第3期15-17,共3页 Jiangsu Electrical Engineering
关键词 汽封改造 精确动平衡 消振 honeycomb seal transformation accuratey dynamic balance vibration elimination
  • 相关文献

参考文献1

  • 1施维新.汽轮发电机组振动及事故[M].北京:中国电力出版社,1998..