摘要
本文论述变风量空调系统中空气处理机组的送风温度、送风量、新风量等参数的控制方式和设定值的选择,提出了完整的变风量空调系统中空气处理机组的控制方案,并讨论变风量空调系统过渡季运行方案。
This paper concentrates upon the control strategy and setpoint determination for supply air temperature,supply air volume,fresh air volume of AHU in VAV air conditioning system,provides a complete AHU control scheme for VAV system. The transitionseason operation plan of VAV system has also been discussed.
出处
《建筑科学》
1998年第3期29-32,61,共5页
Building Science