本文通过几年来的实际使用经验,详细叙述了小断面一次码烧隧道窑实施正压排潮工艺后取得的效果,并对其正压排潮干燥段的结构进行了阐述.
<Abstract>Through several years of practical use, this article recommends in detail the effects of using positive pressure drying process in small cross-section once setting tunnel kiln and describes in detail the structure of positive pressure zone.