期刊文献+

基于发泡聚氨酯对大坝保温的研究 被引量:2

Research on heat insulation of a dam based on foaming polycurethane
下载PDF
导出
摘要 佛子岭混凝土连拱坝裂缝产生的主要原因是混凝土的温度变形和早期混凝土的干缩变形,文章介绍了保温层的工作原理,研究了裸露坝体的温度效应、表面有保温层的坝体温度效应;研究表明采用发泡聚氨酯对大坝进行保温,能有效地降低大坝的温度应力。 The main factors that cause cracks in the Fuziling multi-arch concrete dam are temperature deformation and desiccation deformation of the concrete in its earl period. This paper introduces the working principles of thermal insulation, and researches the temperature effect of the bare dam and the thermal insulation on the dam surface. The results show that the temperature stress of the dam is reduced effectively when the dam is heat-insulated by foaming polycurethane.
出处 《合肥工业大学学报(自然科学版)》 CAS CSCD 北大核心 2009年第5期742-744,共3页 Journal of Hefei University of Technology:Natural Science
关键词 混凝土连拱坝 发泡聚氨酯 保温 温度应力 multi-arch concrete dam foaming polyeurethane heat insulation temperature stress
  • 相关文献

参考文献8

  • 1安徽水利建设安装总公司.佛子岭水库除险加固工程施工组织设计[R].合肥:安徽水利建设安装总公司,2004.
  • 2SL258--2000,水库大坝安全评价导则[S].
  • 3安徽省水利勘测设计院.佛子岭水库除险加固工程初步设计[R].合肥:安徽省水利勘测设计院,2002.
  • 4YBJ226-91,喷射混凝土施工技术规程[S].
  • 5SL282-2003.混凝土拱坝设计规范[S].[S].,..
  • 6安徽省水利勘测设计院.佛子岭水库大坝保温设计[R].合肥:安徽省水利勘测设计院,2002.
  • 7中国水利水电科学研究院.佛子岭连拱坝静力、动力分析和抗震安全复核[R].北京:中国水利水电科学研究院,2002.
  • 8SL203-97,水工建筑物抗震规范[S].

共引文献90

同被引文献15

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部