摘要 某核电站凝结水处理系统投运后导致蒸汽发生器液相中SO4浓度升高,为此,分析了凝结水处理系统存在的诸多问题,如树脂混合、树脂分离及树脂扰动等。通过在混床内增加二次混合设备,采用先进的高塔分离法,设计均匀的布水装置,选用优质的离子交换树脂等措施,将使问题得到解决。 In a nuclear power station, after the condensed water treating system was put into operation, the concentration of SO4^2- in liquid phase in the steam generator increased. For solving this problem, this paper analyzes the problems existing in the condensed water treating system, such as resin mixing, resin separating,and resin disturbing. By adding secondary mixing device in mixing bed and adopting the advanced high -tower separation method, designing well -proportioned condensate distribution device, and choosing ion exchange resin of high quality, this problem is solved.
出处 《热力发电》 CAS 北大核心 2009年第5期77-79,90,共4页 Thermal Power Generation
关键词 核电站 凝结水处理 离子交换树脂 混床 蒸汽发生器 nuclear power station condensed water treatment ion exchange resin mixing bed steamgenerator
  • 相关文献

参考文献11

  • 1洪锦从.岭澳核电站第1燃料循环WANO化学指标状况研究[J].广东电力,2005,18(5):4-9. 被引量:6
  • 2贺禹,陈乐荣,方军.ATE运行造成SO4^2-(APG)增高原因初步分析[R].大亚湾核电站,1998.
  • 3肖征文.凝结水系统调试,岭澳核电工程实践与创新,调试启动卷(Ⅱ)[M].原子能出版社,2002:90-102.
  • 4陈永军,张国庆.凝结水净化处理系统调试,岭澳核电工程实践与创新,调试启动卷(Ⅱ)[M].原子能出版社,2002:192-198.
  • 5洪锦从.化学接产准备,岭澳核电工程实践与创新,生产准备卷[M].原子能出版社,2002:221-224.
  • 6洪锦从.化学人员工程参与,岭澳核电工程实践与创新,生产准备卷[M].原子能出版社,2002:368-370.
  • 7朱镭,梁桥洪,熊京川,朱兴宝.压水堆核电站二回路的水汽质量[J].上海电力学院学报,2006,22(2):121-123. 被引量:6
  • 81000MW压水堆核电站化学与放射化学技术规范[S].
  • 9朱兴宝,熊京川,梁桥洪.核电站凝结水混床处理技术的剖析[A].中国电机工程学会第九届青年学术会议论文[C].中国水利水电出版社,2006:1317-1321.
  • 10朱兴宝,梁桥洪,熊京川.核电站凝结水处理用树脂的选择原则[A].中国电机工程学会第九届青年学术会议论文[C].中国水利水电出版社,2006:1322-1324.