摘要 介绍了国华三河电厂二期2×300MW机组的烟气脱硝自动控制系统,该控制系统的控制策略不仅算法过程简单、参数整定方式清晰、对象识别速度快,而且充分利用随动关系对应的摩尔比,以及用比例控制方式,解决了烟气出口NOx浓度因大惯性而难于控制的问题。对实际运行参数检验表明,该控制系统鲁棒性强,达到了各项控制指标,较好地满足了脱硝自动化控制的要求,并具有较强的通用性和实用性。 The automatic control system of flue gas denitrification for 2 × 300 MW units in Sanhe Power Plant has been presented, the control strategy of said control system not only has simple algorithm process, but also uses the mole ratio corresponding to the follow- up relation and the proportional control mode,solving the difficult problem of controlling the concentration of NOx at exit of flue gas due to its large inertia. Through inspection of actual operation parameters, it shows that the said control system has strong robustness,satisfying better the requirements of automatic control in flue gas denitrification, having stronger universality and practicality for selective catalystic reduction(SCR)denitrification system.
出处 《热力发电》 CAS 北大核心 2009年第5期91-93,112,共4页 Thermal Power Generation
关键词 国华三河电厂 300 MW机组 SCR 烟气脱硝 控制 Guohua Sanhe Power Plant 300 MW unit SCR flue gas denitrification control
  • 相关文献

参考文献2

  • 1魏恩宗,高翔,骆仲泱,倪明江,岑可法.电晕放电烟气脱硝机理探讨[J].电站系统工程,2003,19(5):1-3. 被引量:35
  • 2中国电力投资集团公司.中国燃煤电站脱硫和脱硝技术现状与发展[C]//中国科协2004年学术年会电力分会场暨中国电机工程学会年会论文集.北京:中国电机工程学会,2004.

二级参考文献23

  • 1Chang J S, et al. Corona Discharge Processes [J]. IEEE Trans. on Plasma Science, 1991,19(6): 1 152-1 165.
  • 2Masuda S, et al. Control of NOx by Positive and Negative Pulsed Ciriba Discharge [J]. IEEE/IAS Annu Conf, 1986:1 173-1 182.
  • 3Mizuno A, et al. A Device for Removal of Sulfur Dioxide Exhaust Gas by Pulsed Execration of Free Electrons [C]. Proc of IEEE/LAS,1984 Annual Conf, 1984:1 025-1 182.
  • 4Tokunaga O, Suzuki N. Radiation chemical reactions in NOx and SO2 removals from flue gas [J]. Radiat Phys Chem ,1990,24(1):145 - 165.
  • 5Senichi Masuda, Hideyuki Nakao. Comrol of NOx by positive and negative pulsed corona discharges [J]. IEEE Transactions on Industry Applications, 1990, 26(2): 374-383.
  • 6Keping Yah, Hexing Hui, et al. Corona induced non-thermal plasmas:fundamental study and induslrial applications [J]. Journal of Electrostatics, 1998,44: 17-39.
  • 7Tomio Fujii. Removal of NOx by DE Corona Reactor with Water [J].Journal of Electrostatics, 2001, 51: 8-14.
  • 8Yamamoto T, et al. Triangle-shaped DC Corona Discharge Device for Melecular Decomposition [J]. IEEE Trans. on Ind Appl, 1982, 25(4):743-749.
  • 9Chang J S, Hayama M, et al. Ar-NH3 Mixture gas positive column plasma [J]. Chemical Engineering Science. 1989, 5:351 -355.
  • 10Bernie M Penetrante, Mark C Hsiao, et al. Comparison of electrical discharge techniques for non-thermal plasma processing of NO in N2 [J]. IEEE Trans. On plasma science. 1995,23(4): 679-687.

共引文献40

同被引文献103

引证文献26

二级引证文献121

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部