期刊文献+

酶法测定血清淀粉酶方法及临床应用 被引量:1

Enzymatic method to determine α-Amylase (AMS) and the clinical application
下载PDF
导出
摘要 介绍使用国产葡萄糖苷酶来代替进口的葡萄糖苷酶测定血清α-淀粉酶.测定缓冲液为0.1mmol/L磷酸盐缓冲液(pH=6.8)。葡萄糖苷酶浓度>8000U/L.该法测定血清α-淀粉酶至少在0~420U/L内有良好的线性、批内不精密度<2%,日间不精密度<3%,与PNP方法比较有良好的相关性,特异性也较高,可满足医院临床使用的要求。 This paper introduces a new method for measuring α-Amylase(AMS) in serum. This method usedthe local made natural glucosidase. The concentration of phosphate buffer was 0.1mmol /L and glucosidase wasmore than 800 U/L. The linearity of the method extended to 420U/L. The imprecision have within run and be-tween days was less than 2 % and 3% respcctively and the relativity with PNP method was very good. Ourmethod is special and sensitive for measuring a-AMS and will be satisfied by clinical demand-
作者 赵海舰 郭健
出处 《陕西医学检验》 1998年第2期9-12,共4页 Shaanxi Journal of Medical Laboratory Sciences
关键词 葡萄糖苷酶 酶法 血清淀粉酶 临床应用 α-Amylase Glucosidase Linearity