期刊文献+

蛋白质组学质谱数据预处理技术综述 被引量:9

Progress in the Preprocessing of Mass Spectrometry Proteomics Data
下载PDF
导出
摘要 基于质谱技术的蛋白质组学数据分析,是识别新型生物标记物模式的有效手段。质谱仪检测的数据含有大量潜在信息,但数据很容易被系统误差和噪声污染。蛋白质组学质谱数据预处理的目的在于抑制噪声、数据简约和增加谱可比性等,是增强生物学相关信息的至关重要步骤。只依赖质谱仪中的软件进行数据预处理存在一定局限,需要额外工具辅助。从数据简约、谱线平滑、基线校正、标准化、谱峰提取与量化、谱峰联配等方面介绍典型的预处理技术,对预处理方法存在的问题进行讨论,并就发展趋势进行展望。 Mass Spectrometry based proteomies analysis is a powerful approach for identifying novel biomarkers patterns in biological samples. Though data produced by mass spectrometers contains potentially huge amount of information, they are often interferred by errors and noises due to sample preparation and instrument approximation. Preprocessing is crucial for mass spectrometry data in removing noises, reducing the amount of data, making spectra comparable, and allowing us to focus on the biologically relevant information. However, data preprocessing using the software of mass spectrometer is not enough, and needs some extra tools to assist. This paper introduced different classical techniques for spectra preprocessing, including data reduction, smoothing, baseline correction, normalization, peak detection and quantification and peak alignment as well. Finally, future works and some key problems about mass spectrum preprocessing were discussed.
作者 孟辉 洪文学
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2009年第3期469-475,共7页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(60671025) 河北省自然科学基金(F2008000895)
关键词 蛋白质组学质谱 数据预处理 数据质量 proteomic mass spectrometry data preprocessing data quality
  • 相关文献

参考文献39

  • 1Petricoin EF, Ardekani AM, Hitt BA, et al. Use of proteomie patterns in serum to identify ovarian cancer [J]. The Lancet, 2002, 359: 572- 577.
  • 2曹志成.蛋白质芯片SELDI-TOFMS技术的研究进展及其在临床中的应用[J].生物工程学报,2006,22(6):871-876. 被引量:15
  • 3Laure FM, Matthew AR, Laurent BF. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in clinical chemistry [J]. Clinica Chimica Acta, 2003, 337(1-2):11- 21.
  • 4Baggerly KA, Morris JS, Coombes KR. Reproducibility of SELDITOF protein patterns in serum: comparing datasets from different experiments [J]. Biolnformatics, 2004,20(5) : 777 - 785.
  • 5Malyarenko DI, Cooke WE, Adam BL, et al. Enhancement of sensitivity and resolution of surface-enhanced laser desorption/ ionization time-of-flight mass spectrometric records for serum peptides using time-series analysis techniques []]. Clin Chem, 2005, 51:65 - 74.
  • 6Morris JS, Coombes KR, Koomen J, et al. Feature extraction and quantification for mass spectrometry in biomedical applications using the mean spectrum [J]. Bioinformatics, 2005, 21(9): 1764- 1775.
  • 7Hong Huixiao, Dragan Y, Epstein J, et al. Quality control and quality assessment of data from surface-enhanced laser desorption/ ionization (SELDI) time-of flight (TOF) mass spectrometry (MS) [J]. BMC Bioinformatics, 2005, 6(Suppl 2):S5.
  • 8Dijkstra M, Vonk RJ, Jansen RC. SELDI-TOF mass spectra: A view on sources of variation [ J 1. Journal of Chromatography B, 2007, 847:12 - 23.
  • 9Yasui Y, Pepe M, Thompson ML, et al. A data-analytic strategy for protein biomarker discovery: profiling of high-dimensional proteomic data for cancer detection [J]. Biostatistics, 2003, 4(3) : 449 - 463.
  • 10Ressom HW, Varghese RS, Drake SK, et al. Peak selection from MALDI-TOF mass spectra using ant colony optimization [ J ]. Bioinformaties, 2007, 23(5) : 619 - 626.

二级参考文献4

共引文献14

同被引文献80

引证文献9

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部