摘要 为进一步探讨丝状菌污泥膨胀的影响因素和建立控制策略,以MUCT工艺为研究对象,考察低温对活性污泥沉降性能的影响及相应的污泥膨胀的控制措施.结果表明:当系统的反应温度低于15℃时,Microthrixparvicella大量生长繁殖,改变了活性污泥的结构,发生污泥膨胀,SVI值最高达到381 mL/g;通过采取控制系统的反应温度为25±1℃、污泥龄减少至6 d、硝化液回流比α减小为2.5以及混合液回流比γ增大为1等措施可有效抑制Microthrixparvicella的生长繁殖,提高污泥的沉降性能,经过36 d的运行,使SVI值降至127 mL/g;膨胀期与恢复期系统对COD、TP的去除效果较好,而且膨胀期对TN的去除效果也较好,但在恢复期则因污泥龄的降低而明显下降. In order to further find out the factors causing sludge bulking and establish the corresponding control strategies, the effect of low temperature on sludge settling characteristics and the control strategies for inhibiting the growth of filamentous bacteria were investigated based on MUCT processes. The results show that the sludge bulking occurs in the reactor due to the alteration of activated sludge' s structure at the reaction temperature below 15 ℃, which results in the excessive growth of microthrix parvicella, and the maximum SVI value reaches 381 mL/g. The excessive growth of microthrix parvicella can be efficiently inhibited by controlling the reaction temperature at 25 ± 1 ℃, decreasing SRT to 6 days, and decreasing the nitrate recireulation ratio α to 2. 5 or increasing the mixed liquor recirculation ratio γ to 1. The SVI value is decreased to 127 mL/ g after the operation for 36 days. The good removal effieiencies of COD and TP are achieved during the bulking and reestablishing periods. The removal efficiency of TN is also good during the bulking periods, but the adverse result is that its removal rate is reduced with the decrease of SRT during the reestablishing periods.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2009年第4期67-71,共5页 Journal of Harbin Institute of Technology
基金 国家高技术研究发展计划资助项目(863-2004601020-03)
关键词 MUCT工艺 污泥膨胀 反应温度 污泥龄 MUCT process sludge bulking reaction temperature sludge retention time
  • 相关文献

参考文献18

  • 1TSAI M W, WENTZEL M C, EKAMA G A. The effect of residual ammonia concentration under aerobic conditions on the growth ofMicrothrix parvicella in biological nutrient removal plants [ J ]. Wat Res, 2003, 37 : 3009 - 3015.
  • 2WAGNER M, LOY A. Bacterial community composition and function in sewage treatment systems [ J ]. Curr Opin Biotechnol, 2002, 13 (3) : 218 - 227.
  • 3孙寓姣,王勇.膜-生物反应器中污泥膨胀对生物相及微生物多样性影响[J].哈尔滨工业大学学报,2006,38(6):887-888. 被引量:5
  • 4XIE B, DAI X C, XU Y T. Cause and pre-alarm control of bulking and foaming by Microthrix parvicella --A case study in triple oxidation ditch at a wastewater treatment plant [ J ]. Journal of Hazardous Materials, 2007, 143 : 184 - 191.
  • 5SCRUGGS C E, RANDALL C W. Evaluation of filamentous microganism growth factors in an industrial wastewater activated sludge system [ J ]. Wat Sci Tech, 1998, 37(4-5): 262-270.
  • 6MADONI P, DAVOLI D, GIBIN G. Survey of filamentous microorganisms from bulking and foaming activated- sludge plants in Italy[ J ]. Wat Res, 2000, 34(6) : 1767 - 1772.
  • 7郝晓地,朱景义,曹秀芹.污泥膨胀形成机理及控制措施研究现状和进展[J].环境污染治理技术与设备,2006,7(5):1-9. 被引量:22
  • 8MARIA R. Operation with biological nutrient removal with stable nitrification and control of filamentous growth [J]. Wat Sci Tech, 1998, 37(4/5): 549-554.
  • 9ANDREASEN K, SIGVARDSEN L. Experiences with sludge settleability in diferent process alternatives for nutrient removal[J]. Wat Sci Teeh, 1996, 33 (12) : 137 - 146.
  • 10陈红英,王增长,牛志卿.生物脱氮除磷工艺中的丝状菌[J].环境污染与防治,2005,27(4):266-268. 被引量:3