摘要
大功率鼠笼式异步电动机常采用降压启动,降压启动的方法有多种,Y-△降压启动是其中常用的一种,在此介绍一台采用Y-△降压启动的深井泵的2例典型故障,从不同的角度对故障加以分析和判断,并提出实际解决的方法和整改措施。
High power squirrel - cage induction motors used by step - down start, step - down to start a number of means, star - shaped and triangular - type step - down start is one kind commonly used, here the author describes two cases of the use of star - shaped and triangular - type on deep well pump step - down start typical fault, from a different perspective on the failure to analyzing and judge, and to propose practical solutions and rectification measures.
出处
《煤矿机械》
北大核心
2009年第6期210-211,共2页
Coal Mine Machinery
关键词
典型故障
Y-△降压启动
Y-△切换
接触不良
typical fault
star - shaped and triangular - type step - down start
star - shaped and triangular - type conversion
exposure bad