期刊文献+

眼内压力测量技术的研究 被引量:4

The Study on Techniques for Monitoring Intraocular Pressure
下载PDF
导出
摘要 本文详细介绍了用于单次测量的各种眼压计的原理结构、应用范围,同时也给出了连续眼压监测技术的最新研究方法及传感器系统设计现状等。 This paper aims at providing an up-to-date review of principle and application of various tonometers, and analyzes the new techniques of diurnal IOP monitoring and design of sensor system abroad, requirements and test methods for GB/T 14710-93.
出处 《中国医疗器械杂志》 CAS 2009年第3期202-206,共5页 Chinese Journal of Medical Instrumentation
关键词 青光眼 眼压计 连续眼压测量 Glaucoma, tonometer, continuous lOP measurement
  • 相关文献

参考文献10

  • 1Andrzej Hachol,Marta Grabowska.Investigation of dynamic parameters of ophthalmic tonometric transducers[J].Proc.SPIE 2002,4887:124-131.
  • 2Matteo Leonardi,Peter Leuenberger,Daniel Bertrand,et al.First Steps toward Noninvasive Intraocular Pressure Monitoring with a Sensing Contact Lens[J].Investigative Ophthalmology & Visual Science,Sep.2004,45,(9):3113-3117.
  • 3Schmidt Theo AF.The clinical Application of the Goldmann Applanation Tonometer[J].AMJ Ophthalmol,1960,49-967.
  • 4Marcio Marc Abreu.Apparatus and Method for Noninvasive Measurement of Analytes from the Conjunctiva using Mid-Infraded Radiation.United States Patent[J],US7137952B2,Jul.22,2008.
  • 5Mohammed K.EIMallah,Sanjay G.Asrani.New ways to measure intraocular pressure[Jl.Curr Opin Ophthalmol,2008,19:122-126.
  • 6王溪,窦宏亮,高富军.昼夜眼压波动及其在青光眼治疗中的意义[J].国外医学(眼科学分册),2005,29(3):187-190. 被引量:6
  • 7Kalyan C.Katuri,Sanjay Asrani,Melur K.Ramasubramanian.Intraocular Pressure Monitoring Sensors[J].IEEE Sensor Journal,2008,8(1):13-19.
  • 8Matteo Leonardi,Peter Leuenberger,et al.Intraocular pressure recording system[J].United States Patent,US7137952B2,Nov.21,2006.
  • 9Wilfried Mokwa,Uwe Schnakenberg.Micro-Transponder Systems for Medical Applications[J].IEEE Transactions on Instrumentation and Measurement,Dec.2001,50(6):1551-1555.
  • 10Po-Jui Chen,Damien C.Rodger,Mark S.Humayun,Yu-Chong Tai.Implantable Micromechanical Parylene-based Pressure Sensors for Unpowered Intraocular Pressure Sensing[J].J.Micromech.Microeng,2007,17:1931-1938.

二级参考文献19

  • 1Kano K, Kuwayama Y. Diurnal variation of intraocular pressure in normal-tension glaucoma. Nippon Ganka Gakkai Zasshi, 2003,107:375-379.
  • 2Hughes E, Spry P, Diamond J, et al. 24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review. J Glaucoma,2003,12: 232-236.
  • 3Sihota R, Saxena R, Agarwal HC, et al. Crossover comparison of timolol and latanoprost in chronic primary angle-closure glaucoma.Arch Ophthalmol, 2004,122:185-189.
  • 4Konstas AG, Mylopoulos N, Karabatsas CH, et al. Diurnal intraocular pressure reduction with latanoprost 0. 005 % compared to timolol maleate 0.59% as monotherapy in subjects with exfoliation glaucoma. Eye, 2004,18:893-899.
  • 5Konstas AG, Kozobolis VP, Lallos N, et al. Daytime diurnal curve comparison between the fixed combinations of latanoprost 0. 005 % /timolol maleate 0.5 % and dorzolamide 2 %/timolol maleate 0.5 %.Eye, 2004,18:1264-1269.
  • 6Agarwal HC, Sihota R, Das C, et al. Role of argon laser trabeculoplasty as primary and secondary therapy in open angle glaucoma in Indian patients. Br J Ophthalmol, 2002,86:733-736.
  • 7Medeiros FA, Pinheiro A, Moura FC, et al. Intraocular pressure fluctuations in medical versus surgically treated glaucomatous patients. J Ocul Pharmacol Ther, 2002, 18:489-498.
  • 8Wilensky JT, Zeimer RC, Gieser DK, et al. The effects of glaucoma filtering surgery on the variability of diurnal intraocular pressure. Trans Am Ophthalmol Soc, 1994,92: 377-381.
  • 9Schwartz K, Budenz D. Current management of glaucoma. Curr Opin Ophthalmol, 2004, 15:119-126.
  • 10Asrani S, Zeimer R, Wilensky J, et al. Large dinurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J Glaucoma, 2000, 9:487-488.

共引文献5

同被引文献25

  • 1赵梅生,张忠君,马洪顺,孙伟,李小倩.人眼角膜黏弹性实验研究[J].生物医学工程学杂志,2005,22(3):550-554. 被引量:14
  • 2祝远方,郭文毅.新型非接触式眼压分析仪ORA与Goldmann压平眼压计的比较[J].中国实用眼科杂志,2007,25(5):521-523. 被引量:6
  • 3十合晋一.气体轴承设计、制作与应用[M].韩焕臣译.北京:宇航出版社,1988.
  • 4Kanngiesser H E, Kniestedt C,Robert Y C. Dynamiccontour tonometry: presentation of a new tonometer[J]. Journal of Glaucoma?2005 ,14(5): 344-350.
  • 5Lam A K,Chan R,Lam C H. The validity of a newnoncontact tonometer and its comparison with theGoldmannn tonometer [J]. Optometry and VisionScience,2004,81(8):601-605.
  • 6Pepose J S,Feigenbaum S K,Qazi M A,et al. Changesin corneal biomechanics and intraocular pressurefollowing LASIK using static, dynamic and noncontacttonometry [j]. American Journal of Ophthalmology,2007,143(1):39-47.
  • 7Lam A, Chen D, Chiu R, et al. Comparison of IOPmeasurements between ORA and GAT in normalChinese[J]. Optometry and Vision Science,2007,84(9):909-914.
  • 8Kempf R,Kurita Y,Lida Y,et al. Understanding eyedeformation in non-contact tonometry[C] // Proceedingsof the 28th Annual International Conference of theIEEE Engineering Medicine and Biology Society,August 30-September 3,2006,New York,NY.Piscataway:IEEE Press,2006 ,1:5428-5431.
  • 9Han Y M,Bryanston-Cross P J,Lee W K,et al. Activenon-contact tonometer for glaucoma detection [ J].Optics in Health Care and Biomedical Optics:Diagnostics and Treatment ?2002,4916: 143-150.
  • 10Ogbuehi K C? Almubrad T M. Accuracy and reliabilityof the Keeler Pulsair EasyEye non-contact tonometer[J]. Optometry and Vision Science, 2008? 85( 1 ):61-66.

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部