摘要 汽车仪表中的光源布置决定着光源光照度分布从而最终影响汽车背景光的亮度一致性。本文讨论了汽车背景光发展现状及新型光源:发光二极管(LED)作为背景光源的应用情况,分析了目前LED在汽车背景光应用中存在亮度不一致的情况,着重研究了光源布置对汽车背景光亮度一致性的影响,提出了一种通过优化光源布置中相邻LED间距提高汽车背景光亮度一致性的方法。该方法在保证视觉亮度一致性的情况下充分利用了LED的光效,优化了LED的使用数量。实际汽车背景光部件设计中的成功应用证明了该方法的有效性。 Luminance distribution is determined by light source alignment, which influences the quality of automobile dashboard background light system. In this paper, the development status of automobile dashboard background light system and the new type source LED used as backlight are discussed. Then the brightness ineonformity of LED automobile dashboard background light system at present is analyzed. The backlight alignment is mainly studied and a method to improve the uniformity of brightness in an automobile dashboard backlight system is put forward. The method optimizes the distance of LEDs and designs the alignment of LED array with an optimal distance, also optimizes the amount of LEDs. This method was applied successfully in the part design of a background light system. Result shows that this method is effective.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2009年第5期1078-1082,共5页 Chinese Journal of Scientific Instrument
关键词 汽车背景光 LED 优化间距 一致性 automobile baeklight LED distance optimization uniformity
  • 相关文献

参考文献6

二级参考文献22

  • 1Anderson S J.Holliday IE Night driving:effects of glare from vehicle headlights on motion perception.Ophthalmic Physiol Opt 15:545 ~551,1995
  • 2Brabyn J,Schneck M E.Haegerstrom-Portnoy G,Steinman B.Vision test performance and accidentproneness in drivers over the age of 55.In:Vision science and its applications,technical digest series,vol.2.Optical Society of America,Washington,1994,pp.210~ 213
  • 3Lachenmayr B,Berger J,Buser A,Keller O.Reduced visual capacity increases the risk of accidents in street traffic,Ophthalmologe 95,1998,44 ~ 50
  • 4Harms H.Nolte W.Anleitung f_r die augen_rztliche Untersuchung und Beurteilung der Eignung zum F_ hren yon Kraftfahrzeugen der DOG.In:Conrads H,Gramberg-Danielsen B (eds) Richtlinien und Untersuchungsanleitungen,Berufsverband der Augen_rzte Deutschlands Kaden,Heidelberg,1984,p 43
  • 5Maria C.Puell.Mesopic contrast sensitivity in the presence or absence of glare in a large driver population.Graefe's Arch Clin Exp Ophthalmol 242:2004,755 ~ 761
  • 6Nagy ZZ,Munk_csy G,Krueger R.Changes in mesopic vision after photorefractive keratectomy for myopia.J Refract Surg 18:2002,249~252
  • 7Lungershausen A,Eckhardt S K,Holcomb J M,et al.Light design:the software dilemma[J].SPIE,1995,3296:53~61.
  • 8Stevenson M A,Campillo C J Jenkins D G.,Advanced optical system simulation in a coupled CAD/ optical analysis[J].SPIE,1999,3634:112~118.
  • 9Freniere E R,Tourtellott J.A brief history of generalized raytracing[J].SPIE,1996,3130:170~178.
  • 10Coffe K L.Y,Priestley K J,Mahan J.R.,M,et al.Diffraction models of radiation entering an aperture for use in a Monte Carlo ray-trace environment[J].SPIE,1998,3429:213~219.