摘要
强迫风冷封闭母线是封闭母线发展的趋势。针对强迫风冷封闭母线的制冷问题,在建立制冷系统的基础上,详细分析制冷风机、换热装置的选择与安装,为强迫风冷封闭母线的实际应用提供了参考借鉴。
The forced air-cooling enclosed bus-bar is the development trend of the enclosed bus-bar. For the cooling problem from the forced air-cooling enclosed bus-bar, on the basis of establishing cooling systerm, we analyzes in detailed the selection and installation of cooling fan and heat-exchanger, which provides reference for the application of forced air-cooling enclosed bus-bar.
出处
《水力发电》
北大核心
2009年第4期71-73,共3页
Water Power
基金
辽宁省教育厅资助项目(2004D043)
关键词
强迫风冷
封闭母线
制冷风机
换热装置
forced air-cooling
enclosed bus-bar
cooling fan
heat-exchanger