摘要
为了达到节能降耗的目的,对火力发电厂1000MW机组冷却水系统1台机组配3台冷却水泵单元制、1台机组配2台冷却水泵单元制和扩大单元制3种配置进行技术经济比较。从工程费用、冷却水泵的年耗电量及发电机组的微增出力几个方面综合分析讨论认为:1台机组配3台冷却水泵单元制冷却水系统对于双背压凝汽器的超大型机组是较为经济合理的冷却水泵配置和运行方式。
For purpose of energy-saving and cost-reducing, three cooling water pumps for one unit system, two cooling water pumps for one unit system and expanding unit system of 1 000 MW thermal power units were compared in technology and economic. By generally analyzing and discussing on construction costs, annual electrical power consumption of the cooling water pumps and output correction of units, the conclusion was that three cooling water pumps for one unit system would be more economical and rational on scheme and operating for super-large power units with a dual-pressure condenser.
出处
《中国电力》
CSCD
北大核心
2009年第6期11-14,共4页
Electric Power
关键词
冷却水泵
单元制
扩大单元制
年总费用
年耗电费用
凝汽器面积
冷却倍率
cooling water pumps
unit system
expanding unit system
annual general expense
annual electrical power consumption expense
condenser area
cooling water ratio