摘要
研制了磷酸三丁酯(TBP)碳糊修饰电极,在含1-苯基-3-甲基-4-苯甲酰基-5-吡唑酮(PMBP)的HCl-KCl底液中,通过电位富集,将三元络合物Pb(PMBP)2(TBP)2中的铅富集在电极上,用2.5次微分阳极溶出伏安法测定铅.铅浓度在1.0×10-9~2.5×10-7mol·L-1范围内与峰高呈良好的线性关系.该电极用于铜合金和废水中铅的测定,获得满意结果.
A chemically modified carbon paste electrode was prepared by incorporating tributyl phosphate(TBP) directly into the paste mixture. In the presence of 1 phenyl 3 methyl 4 benzoyl 5 pyrazolone(PMBP), trace lead in HCl KCl supporting electrolyte can be preconcentrated on the electrode. The method showed good linearly for 1.0×10 -9 -2.5×10 -7 mol·L -1 lead(Ⅱ). Many common metal ions have no or little effect on the determination of lead(Ⅱ). The electrode was verified by the determination of trace lead(Ⅱ) in the waste water and alloy.
出处
《分析科学学报》
CAS
CSCD
1998年第2期126-128,共3页
Journal of Analytical Science
基金
湖南省自然科学基金