通过用高浓缩同位素142Ce和140Ce配制9种混合样品,精确测定质谱计的系统误差校正系数,来校正用该仪器测定的天然铈的同位素丰度比,从而建立了准确测定铈同位素丰度的质谱分析方法,用这种绝对质谱法测定的铈相对原子质量是1401157±00008。
A series of nine standard solutions were prepared by blending highly enriched isotopes 142 Ce and 140 Ce,and employed for the determination of correction factor K for the Finnigan mass spectrometer MAT 261.The factor K was then used for the correction of natural Ce isotopic ratios in minerals and chemical reagents measured by this instrument. With this absolute mass_spectrometric method,the relative atomic mass of cerium was found to be 140 115 7±0 000 8.This value was accepted by the IUPAC Commission on Atomic Weights and Isotopic Abundances in 1995.
出处
《分析测试学报》
CAS
CSCD
1998年第3期1-3,共3页
Journal of Instrumental Analysis
基金
国家自然科学基金
关键词
相对原子质量
同位素丰度
质谱法
铈同位素丰度
Cerium,Relative atomic mass,Isotopic abundance,Absolute mass spectrometry