期刊文献+

等离子体质谱测定岩石标准物质中痕量元素——对某些元素定值的探讨 被引量:15

Precise Determination of Trace Element in Standard Reference Rock Sample by ICPMS Discussion on the Recommended Values for Some Trace Elements
下载PDF
导出
摘要 用等离子体质谱(ICPMS)对美国玄武岩标准物质BHVO1、W2和中国玄武岩标准物质GBW07105(GSR3)进行了39种痕量元素分析。三个标准物质的绝大多数元素测定值与标准值在误差范围内一致。GSR3中Cs、Pb、Y、Nb、Tm、Yb等元素的ICPMS测定值与标准值存在不同程度的偏差。用同位素稀释法对GSR3中的Pb做了进一步的精确测定,结合玄武岩的元素地球化学分析,认为GSR3标准物质中上述元素的标准值有必要做进一步的分析工作和修正。 The concentrations of 39 trace elements for two USGS standard basalt samples (BHVO1 and W2) and one Chinese national standard basalt sample GBW 07105 (GSR3) have been precisely determined by ICPMS. The detected values for most trace elements in these standard rock samples are in good agreement with the published recommended values. The analytical results for some trace elements including Y, Cs, Pb, Nb, Tm and Yb, however, differ variably from the recommended values in GSR3. Pb concentration in GSR3 was also determined by isotope dilution method. Based on the trace element geochemical behavior, especially some unique trace element ratios for alkaline basalts, we consider that results by ICPMS for the above elements are more reliable than those of published recommended values. It is suggested that further determination and correction for the recommended values of some trace elements in GSR3 be needed.
出处 《岩矿测试》 CAS CSCD 北大核心 1998年第2期112-116,122,共6页 Rock and Mineral Analysis
基金 中国科学院广州地球化学研究所所长基金
关键词 标准物质 痕量元素 等离子体质谱 玄武岩 岩石 certified reference material, trace element, basalt, inductively coupled plasma mass spectrometry (ICPMS)
  • 相关文献

参考文献8

二级参考文献4

  • 1李冰,岩矿测试,1995年,14卷,254页
  • 2孙亚莉,岩矿测试,1995年,14卷,15页
  • 3曾惠芳,岩矿测试,1995年,14卷,173页
  • 4Xie Q,Geostandards Newsletter,1994年,18卷,53页

共引文献584

同被引文献826

引证文献15

二级引证文献217

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部