期刊文献+

自组装膜电化学免疫传感器测定甲基对硫磷 被引量:3

SAM ELECTROCHEMICAL IMMUNOSENSOR IN DETERMINATION OF METHYL PARATHION
下载PDF
导出
摘要 利用自组装技术将三巯基丙酸固定在金电极上,以1-乙基-3-(3-二甲氨基)碳二亚胺盐酸盐(EDC)和N-羟基硫代琥珀亚胺(NHS)作为活化剂,将甲基对硫磷抗体以共价键形式固定在三巯基丙酸自组装单分子膜修饰的金电极上,制备了一种免疫传感器。根据抗体与抗原之间特异反应前后电极电位的变化对甲基对硫磷进行定量测定,该传感器的检测下限为0.085μg/ml,检测范围为0.5-15μg/ml,并可以再生、重复利用。 An immobilization procedure of antibody on gold electrode is proposed and a SAM (Self-assembled monolayer) electrochemical immunosensor was prepared. A pretreated gold electrode is first immersed in mercaptopropionic acid solution for self assembly through the Au-S covalent bond. Then antibody against methyl pararthion is immobilized to prepare the sensory component. By means of covalent coupling with the activation of 1-ethyl-3-(3-dimethyllaminopropyl) carbodiimide hydrochloride (EDC)) and N-hydroxysulfosuccinimide (NHS). With the immunosensor, the change of electrode potential was recorded to determine the amount of methyl parathion ranging from 0.5 - 15μg/ml with the detection limit of 0.085μg/ml. The regeneration and repeating characteristics were also studied.
出处 《核农学报》 CAS CSCD 北大核心 2009年第3期497-500,共4页 Journal of Nuclear Agricultural Sciences
基金 "十一五"国家高技术研究发展计划(863)(2006AA10Z449)
关键词 甲基对硫磷 电化学免疫传感器 自组装 methyl parathion electrochemical immunosensor self-assembled monolayer
  • 相关文献

参考文献9

二级参考文献52

  • 1冯春梁,孙越,辛君华.抗体在自组装单分子膜上的共价键固定化及其传感性能研究[J].辽宁师范大学学报(自然科学版),2005,28(2):197-199. 被引量:14
  • 2李景虹,程广金,董绍俊.一种新型有序超薄有机膜──自组膜[J].化学通报,1995(10):11-18. 被引量:17
  • 3Sun L,Langmuir,1993年,9卷,1951页
  • 4Li J,J Am Chem Soc,1992年,114卷,2428页
  • 5Bunde R L, Jarvi E J, Rosentreter J J. Piezoelectric quartz crystal biosensors. Talanta, 1998, 46:1223-1236
  • 6Wang H, Shen G L, Yu R Q, et al. Novel immunoassay for Toxoplasma gondii-specific immunoglobulin G using a silica nanoparticle-based biomolecular immobilization method. Analytica Chimica Acta, 2004, 501:37-43
  • 7Li J S, Shen G L, Yu R Q, et al. A piezoelectric immunoagglutination assay for Toxoplasma gonlii antibodies using gold nanoparticles. Biosens Bioelectron, 2004, 19:701-709
  • 8Wu Z Y, Shen G L, Yu R Q, et al. A reusable piezo-immunosensor with amplified sensitivity for ceruloplasmin based on plasmapolymerized film. Talanta, 2004, 62:201-208
  • 9Liu G D, Shen G L, Yu R Q, et al. Renewable amperometric immunosensor for Schistosoma japonium antibody assay. Anal Chem,2001, 73:3219-3226
  • 10Zhang S S, Jiao K, Chen H Y, et al. Detection of ferritin in human serum with a MAP-H2O2-HRP voltammetric enzyme-linked immunoassay system. Talanta, 1999, 50:95-101

共引文献107

同被引文献51

引证文献3

二级引证文献46