期刊文献+

双丝型同步辐射光束位置监测器的参数设计 被引量:6

Parametric design of a double-wire type PBPM for a synchrotron radiation facility
下载PDF
导出
摘要 双丝型同步辐射光束位置监测器(PBPM)基于光电子发射原理,通过光敏丝探测同步辐射的强度。在扫描模式下可以方便地获得光束的强度分布情况,在静止状态时则可以通过两根丝上光电流大小的相对变化对同步辐射光束的位置进行实时监测。本文介绍了这种双丝型PBPM的原理、设计、参数优化及误差分析,及其在北京同步辐射装置上的应用情况。 In this paper, we describe a double-wire photon beam position monitor (PBPM) for monitoring synchrotron radiation (SR) intensity by photosensitive wire based on the principle of photoemission. In scan mode, the SR intensity distribution can be easily obtained. In the smile state, we can realize real-ilme monitoring of the SR beam position by changes of the photoelectron currents of the two wire sensors. The principle, design, parametric optimization, error analysis, and its application in Beijing Synchrotron Radiation Facility (BSRF) are given.
出处 《核技术》 CAS CSCD 北大核心 2009年第6期401-404,共4页 Nuclear Techniques
基金 BEPC II工程项目资助
关键词 光束位置监测器 监测函数 同步辐射 Beam position monitor, Monitor function, Synchrotron radiation
  • 相关文献

参考文献5

  • 1Warwick T,Andresen N,Portmann G,et al.Rev Sci Instr,1995,66(2):1984-1986
  • 2Galimberti A.Proceedings of EPAC'96,June 1996.1728-1730
  • 3Schildkamp W,Pradervand C.Rev Sci Instr,1995,66(2):1956-1959
  • 4Holldack K,Peatman W B,Schroeter T.Rev Sci Instr,1995,66(2):1889-1891
  • 5林顺富,孙葆根,高辉,卢平,申超波,鲍循.一种带有弹簧的丝型同步光位置检测器[J].强激光与粒子束,2007,19(8):1369-1372. 被引量:3

二级参考文献9

  • 1孙葆根,林顺富,何多慧,卢平,徐宏亮,王筠华,曹涌,李吉浩,张春晖,王宝云.合肥光源光位置检测器的标定和应用(英文)[J].强激光与粒子束,2006,18(1):143-146. 被引量:4
  • 2孙葆根,郑普,卢平,徐宏亮,王筠华,王季刚,王宝云.合肥光源新的束团截面及发射度测量系统的研制[J].高能物理与核物理,2006,30(8):792-796. 被引量:7
  • 3林顺富,孙葆根,高辉,卢平.采用对数比处理技术的同步光位置测量系统[J].强激光与粒子束,2006,18(11):1903-1907. 被引量:6
  • 4Galimberti A, Abrami A, Chen Q H, et al, Photon beam position monitors suitable for a local feedback system at ELETTRA[C]//Proceedings of EPAC. 1996: 1728-1730.
  • 5Burger S, Pattison P, Rafael A. Development of a wire detector for the Swiss light source[R]. SNBL, 2000: 17-19.
  • 6Lin S F, Sun B G, Gao H, et al. The study of new signal processing technique in photon beam position monitors[C]//Proceedings of PAC. 2005:4239-4241.
  • 7Mrotzek G, Cernik R, Flaherty J, et al. Photon beam position monitors on the SRS at Daresbury[C]//Proceedings of Europe Particle Accelerator Conference. 1994: 1563.
  • 8Mrotzek G, Fitzgerald J B. Performance and progress of the Daresbury photon beam tungsten vane monitor system[C]//Sth European Particle Accelerator Conference. 1996: 10-14.
  • 9Burger S, Chen Q, Krempasky J, et al. Synchrotron radiation monitors for SLS beamlines[R]. PSI Scientific Report, 2000.

共引文献2

同被引文献51

  • 1陈冬严,林斌,陈钰清.位置敏感探测器(PSD)的研究进展[J].光学仪器,2004,26(4):68-71. 被引量:19
  • 2孙葆根,郑普,卢平,徐宏亮,王筠华,王季刚,王宝云.合肥光源新的束团截面及发射度测量系统的研制[J].高能物理与核物理,2006,30(8):792-796. 被引量:7
  • 3林顺富,孙葆根,高辉,卢平.采用对数比处理技术的同步光位置测量系统[J].强激光与粒子束,2006,18(11):1903-1907. 被引量:6
  • 4姜山,蒋松生,郭宏.一台锯齿形阳极位置灵敏电离室[J].核电子学与探测技术,1996,16(5):374-376. 被引量:3
  • 5黎忠.X射线位置测量系统[C].中科院上海应用物理研究所,2007.
  • 6Hayano H, Kubo K, Mitsuhashi T, et al. Emittance measurement at KEK-ATF damping ring[C].//Proceedings of the 1999 Particle Accel- erator Conference. 1999:2143-2145.
  • 7Koda S, Takabayashi Y, Iwasaki T, et al. Measurement of betatron coupling in SAGA-IS storage ring[C]//Proceedings of the 5th Annual Meeting of Particle Accelerator Society of Japan and the 33rd Linear Accelerator Meeting in Japan. 2008:701-703.
  • 8Parc Y W, Kim C B, Huang J Y, et al. The coherency of synchrotron radiation at Pohang accelerator laboratory[J]. Journal of Synchro- tron Radiation, 2009, 16(5) : 642-646.
  • 9Toshiyuki M. Twelve years of SR monitor development at KEK[C].//AIP Conference Proceedings. 2004, 732:3-18.
  • 10Takabayashi Y, Kaneyasu T, Iwasaki Y, et al. Beam-size measurement system at the SAGA-LS storage ring[C]//Proeeedings of ICALEPCS2009. 2009:140-142.

引证文献6

二级引证文献10