期刊文献+

双源CT冠状动脉成像诊断壁冠状动脉的临床价值 被引量:3

Diagnostic value of dual-source CT coronary parietal artery imaging
下载PDF
导出
摘要 目的:应用双源CT冠状动脉成像探讨壁冠状动脉的检测方法及临床价值。方法:临床怀疑冠心病的500例患者行双源CT冠状动脉成像检查,在工作站进行多平面重组(MPR)、最大密度投影(MIP)及曲面重组(CPR)等后处理并进行分析。结果:在检查的500例患者中190例(38%)有壁冠状动脉存在,其中157例发生在前降支及其分支,16例发生在回旋支及其分支,7例发生在右冠状动脉及其分支,另外10例为多支病变。结论:双源CT冠状动脉成像对壁冠状动脉显示率高,并能对其临床症状进行预测。 Objective:To study the imaging manifestations of parietal coronary artery and the diagnostic value with dual-source CT. Methods:500 patients with clinically suspected coronary heart disease underwent dual-source CT scan, the images were dealt with pest reconstruction method at the workstation, including multi-planar reconstruction(MPR), maximum intensity projection(M/P) and curved planar reconstrnction(CPR).Results:Parietal coronary arteries were found in 190 patients, among them, 157 eases were at the LAD, 16 eases were at the LCX, 7 eases were at the RCA, and multiple arteries involved in 10 cases. Conclusion:Dual-source CT imaging is an effective method in diagnosis of parietal coronary artery.
出处 《医学影像学杂志》 2009年第5期519-521,共3页 Journal of Medical Imaging
关键词 心脏 壁冠状动脉 体层摄影术 X线计算机 Heart Parietal coronary artery Tomography, X-ray computed
  • 相关文献

参考文献4

二级参考文献14

  • 1程流泉,高元桂,孙玮,盛复庚,盖鲁粤,蔡幼铨.屏气三维快速平衡稳态进动序列对冠状动脉狭窄的诊断效能[J].中华放射学杂志,2005,39(3):267-271. 被引量:20
  • 2Lee J,Kwon HM,Hong BK,et al.Total occlusion of left main coronary artery by dilated main pulmonary artery in a patient with severe pulmonary hypertension [J].Korean J Intern Med,2001,16 (4):265 - 269.
  • 3Karube M,Utsunomiya H,Iida T,et al.Total repair of tetoralogy of Fallot in an adult:report of a case without prior treatment at 59 years of age[J].Kyobu Geka,1996,49(5):395 -399.
  • 4Van Ooijen PM,Dorgelo J,Oudkerk M.Noninvasive cononary imaging:CT versus MR (Review).Herz,2003,28:143-149.
  • 5Gerber BL,Coche E,Pasquet A,et al.Coronary artery stenosis:direct comparison of four-section multi-detector row CT and 3D navigator MR imaging for detection:initial results.Radiology,2005,234:98-108.
  • 6Hoffman MB,Wickline SA,Lorenz CH.Qualification of in plane motion of the coronary arteries during the cardiac cycle:implications for acquisition window duration for MR flow qualification.J Magn Reson Imaging,1998,8:568-576.
  • 7Hoffmann MH,Shi H,Manzke R,et al.Noninvasive coronary angiography with 16-detecter row CT:effect of heart rate.Radiology,2005,234:86-97.
  • 8Kopp AF,Schroeder S,Kuettner A,et al.Coronary arteries:retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.Radiology,2001,221:683-688.
  • 9Morgan-Hughes GJ,Roobottom CA,Owens PE,et al.Highly accurate coronary angiography with submillimetre,16 slice computed tomography.Heart,2005,91:308-313.
  • 10Ikonen AE,Manninen HI,Vainio P,et al.Three-dimensional respiratory-gated coronary MR angiography with reference to X-ray coronary angiography.Acta Radiol,2003,44:583-589.

共引文献52

同被引文献17

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部