摘要
就鸭河口电厂350MW汽轮发电机组热力系统及控制方式的特点作了简要介绍,对机组调试过程中主机、辅机及控制方式出现的问题进行了分析与解决,对于机组的启动与运行方式和不完善的设计,提出了一些修改意见与合理建议。
This article gives a brief intruduction to thermal syntax and controlling method of the 350MW generatorturbine in Yahekou Power Plant, and has analyzed and modified the problems of the turbine, auxilary equipments and controlling model in commissioning. It is recommended that some improvement should be done to the incomplete design and model of start-up and operation.
出处
《东北电力技术》
1998年第7期12-16,共5页
Northeast Electric Power Technology