期刊文献+

截面形状对无防火保护钢柱的抗火性能影响分析 被引量:1

RESEARCH ON INFLUENCE OF CROSS-SECTION SHAPE ON FIRE RESISTANCE OF STEEL COLUMN WITHOUT FIRE RESISTINGS
下载PDF
导出
摘要 钢柱的截面形状对钢柱截面温度分布有一定的影响,而钢柱截面温度的分布情况可能导致钢柱的抗火性能提高或者降低。钢柱在不均匀温度分布情况下,由于温度效应的作用,可使钢柱截面局部屈服或者增加附加挠度。对于四面受火钢柱,腹板翼缘厚度的不同会导致腹板截面温度高于翼缘截面,从而导致钢柱截面应力分布不均匀,对钢柱的抗火性能产生影响。通过ANSYS软件分析研究了钢柱在四面受火情况下截面温度分布对钢柱抗火性能的影响,可供钢结构抗火设计参考。 The distributed temperature was influenced by the cross-section shape of the steel column, and the fire resistance of steel column was effected by the temperature distributing. With the asymmetric distribution of temperature, the local yielding would be produced by the column or the deflection would he added. Because of the difference of the thickness of the web plate and the flange, the distributed temperature to the column with four-faced fire would be asymmetric. By using ANSYS program, the influence to the steel column by the distributed temperature of the cross-section was studied, which provided a reference for the fire-resistant design of steel structures.
出处 《钢结构》 2009年第6期75-79,共5页 Steel Construction
关键词 截面形状 钢柱 抗火性能 cross-section shape steel column fire resistance
  • 相关文献

参考文献5

二级参考文献41

  • 1[1]Ali,F. andi O'Connor,D. ,2001 ,Structural performance of rota tionally restrained steel columns in fire, Fire Safety Journal, 36, 679-691
  • 2[2]A1 - Jabri K. S. , Lennon T. , Burgess I. W. and Plank R. J. (1998), Behavior of steel and composite beam column connections in fire,Journal of Constructional Steel Research,46(1-3), 308 - 309
  • 3[3]Bailey C. G. (1998), Enhancement of fire resistance of beams by beam to column connections, New Steel C5onstruction,4,44
  • 4[4]Bailey C. G. (2000a), The influence of the thermal expanson of beams on the structural behavior of columns in steel - framed structures during a fire, Engineering Structures, 22,755 - 768
  • 5[5]Biley C. G. (2000b),Effective lengths of concrete-filled steel square hollow sections in fire, Proceedings of the Institution of Civil Engineers, St ructures & Buildings, 140,169 - 178
  • 6[6]British Standards Institution ( BSI 1990 ), British Standard BS 5950, Structural Use of Steelwork in Buildings, Part 8: Code of Practice for Fire Resistant Design, British Standards Institution, London
  • 7[7]Burgess I. W. , El - Rimawi J. A. and Plank R. J. , (1990), Analysis of beams with non-uniform temperature profile,Journal of Constructional Steel Research, 16,169 - 192
  • 8[8]Burgess I.W. ,Olawale A.O. and Plank R.J. ,(1992),Failure of steel columns in fire,Fire Safety Journal, 18(2), 183 201
  • 9[9]Correia Rodrigues J. P. , Cabrita Neves I. and Valente, J. C. (2000), Experimental research on the critical temperature of compressed steel elements with restrained thermal elongation, Fire Safety Journal,35,77 - 98
  • 10[10]Edwards M. , (1998) ,Reinstatement of concrete filled structural hollow section columns after short duration fires, Phase 2: Stan dard fire tests on full size colunns, Tubes Division Development Project No. S2632, British Steel

共引文献29

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部