影响Fenton法处理晚期垃圾渗滤液CODcr去除因素的研究 被引量:5

Study on factors of removal of COD_(cr) from old landfill leachate by fenton reagent
下载PDF
导出
摘要 采用Fenton试剂氧化法处理晚期垃圾渗滤液,对初始pH、H2O2/Fe2+比、H2O2投加量及反应时间等影响化学需氧量(COD)去除率的各因素进行了研究。得出Fenton试剂氧化法处理晚期垃圾渗滤液的最佳条件为:初始pH为4,H2O2/Fe2+比为5:1,H2O2投加量为0.05mol·L-1,反应时间为2.5h。此时COD去除率可达73.1%。 The factors that affected the removal of chemical oxygen demand(CODcr) from old landfill leachate treated by Fenton reagent, such as sample's initial pH value, H2O2/Fe^2+ dosing ratio, H2O2 dosage and reaction time were investigated in this paper. The results showed that the optimal condition as following, initial pH value of landfill leachate was 4, H2O2/Fe^2+ dosing ratio was 5:1, H2O2 dosage was 0.05 mol.L^-1 and reaction time was 2.5 h. As a result, the removal rate of CODcr from Old landfill leachate was 73.1% under this condition.
出处 《东北农业大学学报》 CAS CSCD 北大核心 2009年第5期50-52,共3页 Journal of Northeast Agricultural University
基金 深圳市科技计划项目资助(SZKJ2007010) 深圳市环保局科研基金资助
关键词 FENTON试剂 晚期垃圾渗滤液 COD去除率 fenton reagent old landfill leachate removal rate of COD