摘要 An S-band cavity BPM is designed for a new injector for HLS (Hefei Light Source). It consists of two cavities that work on 2448 MHz: a re-entrant position cavity tuned to TM110 mode and a reference cavity tuned to TM010 mode. Cut-through waveguides are used as pickups to suppress the monopole signal. Simulations with different assumption of dimension change are performed to evaluate errors caused by mechanical error and give general tolerance. Design of electronics is given. Theoretical resolution of this design is 31 nm. An S-band cavity BPM is designed for a new injector for HLS (Hefei Light Source). It consists of two cavities that work on 2448 MHz: a re-entrant position cavity tuned to TM110 mode and a reference cavity tuned to TM010 mode. Cut-through waveguides are used as pickups to suppress the monopole signal. Simulations with differ- ent assumption of dimension change are performed to evaluate errors caused by mechanical error and give general to- lerance. Design of electronics is given. Theoretical resolution of this design is 31 nm.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第3期133-139,共7页 核技术(英文)
基金 Supported by the Natural Science Foundation of China (10875117) the National "985 Project" (173123200402002)
关键词 BPM 电子学 单极信号 理论 Cavity BPM, Re-entrant, Cut-through waveguide, MAFIA, Omega3p, AD8302
  • 相关文献

参考文献9

  • 1LI Jihao, SUN Baogen, He Duohui, et al. HEP & NP (in Chinese), 2007, 31 (1): 96-100.
  • 2Sargsyan V. Tesla Reports, 2004, 3: 1-9.
  • 3Slaton T, Mazaheri G, Shintake T. Development of nanometer resolution C-band radio frequency beam position monitors in the final focus test beam. Proc. of LINAC98.Chicago, 1998: 911-913.
  • 4Lorenz R. Cavity beam position monitors, Proc. of 1998 Beam Instrumentation Workshop. SLAC, Stanford, 1998: http://www.slac.stan ford.edu/pubs/confproc/biw98/.
  • 5Maesaka H, Otake Y, Togowa K, et al. Beam position monitor at the SCSS prototype accelerator. Proc. of APAC 2007, Indore: 387-389.
  • 6Walston S, Boogert S, Chung Carl, et al. Nucl Inst Met Phy Res A, 2007, 578: 1-22.
  • 7Lunin A, Romanov G, Solyak N, et al. Design of a submicron resolution cavity BPM for the ILC main linac. Proc. of the DIPAC'07, Venice, 2007: 192q94.
  • 8Li Z. S-band cavity BPM for ILC. The 2005 ILC Physics and Detector Workshop and 2^nd ILC Accelerator Workshop (Snowmass 2005), 2005: http://www.hep.ucl.ac.uk/ lc/T474/Documentafion/ILCAW0901_TALK.PDF.
  • 9AD8302 Data Sheet: http://www.analog.com/static/ imported-files/data_sheets/AD8302.pdf.

同被引文献29

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部