期刊文献+

SPECT imaging of cardiac reporter gene expression in living rabbits

SPECT imaging of cardiac reporter gene expression in living rabbits
下载PDF
导出
摘要 This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSV1-tk) reporter gene in rabbits myocardium by using the reporter probe 131I-2'-fluoro-2'-deoxy-1-β-D- arabinofuranosyl-5-iodouracil (131I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with 131I-FIAU 600 μCi at Day 2 after intramyocardial transfection of Ad5-tk in 1×109, 5×108, 1×108, 5×107 and 1×107 pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1×109, 5×108, 1×108, 5×107, 1×107 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, 131I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse tran- scription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSV1-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed 131I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images qual- ity was obtained at 24~48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5×107 pfu of virus titer. The result could be set better in 1~5×108 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSV1-tk/131I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter gene imaging. The optimal Ad5-tk titer is 1~5×108 pfu and optimal imaging time is 24~48 h after transferred Ad5-tk in rabbit. The imaging of transgene expression in heart might be used for noninvasive imaging of gene therapy in cardiac diseases in human. This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSVI-tk) reporter gene in rabbits myocardium by using the reporter probe ^131I-2'-fluoro-2'-deoxy-l-β-o- arabinofuranosyl-5-iodouracil (^131I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with ^131I-FIAU 600 uCi at Day 2 after intramyocardial transfection of Ad5-tk in 1×10^9, 5×10^8, 1×10^8, 5×10^7 and 1×10^7pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1×10^9, 5×10^8, 1×10^8, 5×10^7, 1×10^7 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, ^131I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse transcription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSVI-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed ^131I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images quality was obtained at 24-48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5×10^7 pfu of virus titer. The result could be set better in 1-5×10^8 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSVI-tk/^131I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter gene imaging. The optimal Ad5-tk titer is 1-5×10^8pfu and optimal imaging time is 24-48 h after transferred Ad5-tk in rabbit. The imaging of transgene expression in heart might be used for noninvasive imaging of gene therapy in cardiac diseases in human.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第3期170-176,共7页 核技术(英文)
基金 Supported by National Natural Science Foundation of China (No.30400176, 30571816)
关键词 SPECT CMV 成像技术 核技术 Reporter gene, Herpes simplex virus 1-thymidine kinase, 2'-fluoro-2'-deoxy-1-β-D-arabinofuranosyl-5- iodouracil, Single photon emission computed tomography, Cardiac
  • 相关文献

参考文献14

  • 1Yla-Herttuala S, Markkanen J E, Rissanen T T. Thends Cardiovasc Med, 2004, 14: 295-300.
  • 2Brewster L P, Brey E M, Greisler H P. Adv Drug Deliv Rev, 2006, 58: 604-629.
  • 3Urbain J L C. J Nucl Med, 2001, 42: 107-108.
  • 4Dobrucki L W, Sinusas A J. Molecular Imaging, 2005, 49: 106-115.
  • 5Tjuvajev J G, Stockhammer G, Desai R, et al. Cancer Res, 1995, 55: 6126-6132.
  • 6Tjuvajev JG, Finn R, Watanabe K, et al. Cancer Res, 1996, 56: 4087-4095.
  • 7Haubner R, Avril N, Hantzopoulos PA, et al. Eur J Nucl Med, 2000, 27: 283-291.
  • 8Inubushi M, Joseph C, Sanjiv S, et al. Circulation, 2003, 107: 326-332.
  • 9Bengel F M, Anton M, Richter, et al. Circulation, 2003, 108: 2127-2133.
  • 10Wen B, Burgman P, Zanzonico P, et al. Eur J Nucl Mol Imaging, 2004, 31: 1530-1538.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部