通过对某热电厂NG-130/39-M2型锅炉及制粉系统的测试,分析了锅炉飞灰和大渣可燃物含量偏高和热效率偏低的原因,并提出了相应的改造措施。改造结果达到了预期改进目标。
Through the tests of a NG 130/39 M 2 boiler installed at a thermal power plant and its pulverized coal system analyzed are some causes leading to the excessively high fly ash and slag combustible content and excessively low thermal efficiency of the boiler.Relevant modification measures are proposed,with the help of which anticipated improvements have been attained.