摘要 对组成土壤源热泵系统的3个回路以及整个系统的制冷和制热工况进行了全面的分析,分别给出了它们的损失、效率、损率、损系数以及热力学完善度的表达式。结果表明:在对系统进行分析时,必须将这几个指标结合起来使用。在整个系统中,损率最大的部件是压缩机,而效率与热力学完善度最低的却是土壤热交换器。因此,压缩机和土壤热交换器是整个系统改进的首要对象。 A comprehensive exergy analysis was carried out for three circuits and whole system of a ground source heat pump (GSHP) at the refrigeration and heating conditions. The analytical formulas of exergy loss, exergy efficiency, exergy loss rate, exergy loss coefficient and thermodynamic perfect degree were derived, respectively. The results show that these exergy indexes should be used synthetically, and the maximum exergy loss rate in the whole system is located in the compressor, while the location of minimum exergy efficiency and thermodynamic perfect degree is the ground heat exchanger. Therefor, the compressor and the ground heat exchanger should be improved primarily.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2009年第6期732-737,共6页 Acta Energiae Solaris Sinica
基金 北京市教育委员会科技发展计划项目(No.KM200710005034) 上海市重点学科建设项目(No.T0503)
关键词 土壤源热泵系统 [火用]分析 [火用]指标 ground source heat pump system exergy analysis exergy indexes
  • 相关文献

参考文献13

  • 1徐亚娟,革非.土壤源热泵的研究与应用[J].制冷与空调(四川),2005,19(4):76-79. 被引量:8
  • 2毕月虹,陈林根.太阳能-土壤热源热泵的性能研究[J].太阳能学报,2000,21(2):214-219. 被引量:60
  • 3Bi Y, Guo T, Zhang L, et al. Solar and ground source heat- pump system [J]. Applied Energy, 2004, 78(2): 231- 245.
  • 4田慧峰,王鹏英,曹伟武.大地耦合热泵系统国内外研究近况[J].制冷与空调,2006,6(3):15-20. 被引量:5
  • 5朱明善.能量系统的炯分析[M].北京:清华大学出版社,1985.
  • 6Hepbasli A, Akdemir O. Energy and exergy analysis of a ground source (geothermal) heat pump system [ J ]. Energy Conversion and Management, 2004, 45(5) :737-753.
  • 7Ozgener L, Hepbasli A, Dincer I. Exergy analysis of two geothermal district heating systems for building applications [J]. Energy Conversion and Management, 2007, 48(4): 1185-1192.
  • 8Hepbasli A. Thermodynamic analysis of a ground-source heat pump system for district heating[J]. International Journal of Energy Research, 2005,29(7): 671-687.
  • 9Akpinara E K, Hepbasli A. A comparative study on exergetic assessment of two ground-source (geothermal) heat pump systems for residential applications [ J ]. Building and Environment, 2007,42(5): 2004-2013.
  • 10荆有印,郑国忠,方月兰,柴保双.地下水源热泵系统的分析[J].煤气与热力,2006,26(5):53-57. 被引量:9

二级参考文献48

共引文献106

同被引文献86

引证文献10

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部