期刊文献+

秒级微动人体经穴阻抗计量检测仪的研制 被引量:3

A secs-level detector for human meridian impedance
下载PDF
导出
摘要 为有效分析人体经穴生物阻抗的波动特性,进而实施经穴疾病关联诊断与中医干预,本小组研制了秒级微动人体经穴阻抗计量检测仪,该仪器最小测试间隔为0.01s,可以0.24s的周期循环跟踪人体24处经穴阻抗微动情况,具有高效无创、操作方便、实时性好等优点.实测数据表明,仪器重复性相对误差〈0.067%,仪器准确度测量的相对误差为0.22%~0.75%,目前同类仪器的相对误差水平为〈0.1%和1%,因此秒级微动人体经穴阻抗计量检测仪可以满足实用要求. With the aim to analysis effectively the volatility of the human meridian impedance, as for the diagnosis of meridian diseases and the traditional Chinese medical intervention, a sees-level detector of human meridian impedance is developed. The minimum test interval of the detector is 0. 01 second and it can track and test meridian impedances at 24-points in a period of 0. 24 second. The developed detector is non-invasive and with high efficiency, it is also easy to use and good in a real time test. Experimental data shows that the relative error of repeatability of the detector is lower than 0. 067% and the relative error of accuracy lies between 0.22% and 0. 75%, while for the existing similar detectors in use, the corresponding values are respectively lower than 0. 1% and 1% ; hence the developed detector can meet the practical requirements very well.
出处 《暨南大学学报(自然科学与医学版)》 CAS CSCD 北大核心 2009年第3期264-268,共5页 Journal of Jinan University(Natural Science & Medicine Edition)
基金 广东省科技攻关项目(32406025) 广东省中医药局科研课题(2060114)
关键词 生物阻抗 秒级微动 低惯性关联 微控芯片 biological impedance secs-level fretting low inertia association micro-chips
  • 相关文献

参考文献9

二级参考文献41

  • 1刘顺英.锁相环原理、设计及其应用[M].北京:人民邮电出版社,1988..
  • 2Ouyang Jing,Proceedings of 20th Annual Int Conference of IEEE Engineering in Medicine and Biology Society,1998年,1446页
  • 3杨福生,生物医学信号的处理和识别,1997年,173页
  • 4刘顺英(译),锁相环原理、设计及其应用,1988年,112页
  • 5顾慎为,阻抗血流图,1986年,129页
  • 6Antoni Ivorra. Bioimpedance Monitoring for physicians:an overview. Biomedical Applications Group. 2003.
  • 7Fiorini RA, Dacquino G, Anogo G et al. Effective Bioimpedance spectroscopy method for evaluation of body cell water compartments. 2nd International conference Bioelectromagnetism, February, 203-204.
  • 8Alcibiades LL, Luis BC, Ricardo ML. Bioelectrical Parameters of the Whole Human Body Obtained Through Bioelectrical Impedance Analysis. Bioelectromagnetics, Vol. 23, pp450-454(2002).
  • 9Geddes LA, ' Electrodes and the measurement of bioelectric events ', New York, Wiley-Interscience, 1979.
  • 10Geddes L.A., 'Who Introduced the Tetrapolar Method for Measuring Resistance and Impedance?'. IEEE Engineering in Medicine and Biology, September-October, 1996, pp. 133-134, 1996.Bragos R., Gamez X, Cairo J., Riu P.J., Godia F., 'Biomass monitoring using impedance spectroscopy', Ann N Y Acad Sci, 873, pp. 299-205. Apr 20, 1999.

共引文献87

同被引文献67

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部