期刊文献+

污秽瓷绝缘子泄漏电流的估算方法 被引量:25

Method of Evaluating Leakage Current of Contaminated Porcelain Insulators
下载PDF
导出
摘要 泄漏电流的检测和分析作为污秽绝缘子在线监测的一种方法近年来引起大量关注。国内外研究表明,泄漏电流受作用电压和环境因素等的影响,但探索绝缘子泄漏电流与各影响因素之间的本质联系较少。为此,以单片的普通悬式绝缘子XP-70为试品,在人工雾室中进行了大量的人工污秽试验,利用最小二乘原理分析得到了作用电压U、盐密ρESDD和相对湿度RH与泄漏电流的具体关系式。结果表明:人工污秽试验中,绝缘子的泄漏电流幅值Ih与作用电压U、盐密ρESDD和湿度RH均有关,盐密、湿度影响较明显;随着ρESDD的增加,Ih按幂函数规律增加,特征指数为0.413;随着U和RH的增加,Ih均按指数函数规律增加,特征指数分别为0.044和9.815。研究结果对于工程中建立基于绝缘子泄漏电流的污秽度评估系统有一定的参考价值。 The measurment and analysis of leakage current is an important means of on-line detection of polluted insulators, which has attracted a lot of research and attentio on it. The previous study results show that leakage current has a correlation with the applied voltage and environment factors, but there is few study about the elemental relation between leakage current and influence factors. According to the test results of the single XP-70 insulator carried in the artificial fog chamber,it is analyzed that the effects of the applied voltage U, the equivalent salt deposit density ρESDO and the relative humidity density RH on the leakage current of the XP-7 insulator based on the least squares algorithm in this paper. The result shows that the peak maxmim of leakage current Ih has a correlation with U, ρESDO and RH, the latter two contribute dominant on Ih. The Ih ineases with the increase of ρESDO by an power function with a postive index whichi is 0. 413, while ineases with the increase of both U and RH by an exponential function with a postive index that is 0. 044 for U and 9. 815 for RH. The result could be used as references to estamnate the contamination condition of insultors based on evaluating leakage current ,which is of great value for providing technical references to the external insulation design and anti-polluting in Western China.
出处 《高电压技术》 EI CAS CSCD 北大核心 2009年第6期1350-1355,共6页 High Voltage Engineering
基金 国家自然科学基金重大项目(90210026) 国家"十一五"科技支撑计划重大项目(2006BAA02A19)~~
关键词 泄漏电流 绝缘子 等值盐密 相对湿度 污秽 最小二乘原理 Leakage current Insulators equivalent salt deposit density relative humidity density contamination least squares algorithm
  • 相关文献

参考文献18

  • 1关志成,毛颖科,王黎明.污秽绝缘子泄漏电流特性研究[J].高电压技术,2008,34(1):1-6. 被引量:74
  • 2李璟延,司马文霞,孙才新,李志伟,杨财伟,邓稼卓.染污绝缘子放电中泄漏电流的频谱变化[J].高电压技术,2008,34(3):455-457. 被引量:16
  • 3张重远,黄彬,王娟,律方成.悬式瓷制绝缘子泄漏电流与表面污秽的关系[J].高电压技术,2008,34(4):655-659. 被引量:20
  • 4Felix A, Gergo G K. Linear stochastic analysis of polluted insulators leakage current[J]. IEEE Transactions on Power Delivery,2002,17(4) :1063-1069.
  • 5Tomotaka. Frequency characteristics of leakage current waveforms of a string of suspension insulators[J]. IEEE Transactions on Power Delivery, 2005,20(1) :481-487.
  • 6Piah M A M, Darus A. Modeling leakage current and electric field behavior of wet contaminated insulators[J]. IEEE Transactions on Power Delivery, 2004, 19(1):432-433.
  • 7Mao Yingke, Guan Zhicheng, Wang Liming, et al. Frequency characters of leakage current on the surface of outdoor insulators in different relative humidity[C]//IEEE Conference on Electrical Insulation and Dielectric Phenomena. Kansas, USA: IEEE,2006 : 692-695.
  • 8张建兴,律方成,刘云鹏,谭磊,赵亚平.高压绝缘子泄漏电流与温、湿度的灰关联分析[J].高电压技术,2006,32(1):40-41. 被引量:29
  • 9Ossama E Gouda, Ghada M Amer. Factors affecting the leakage current bursts of high voltage polluted insulators[C]// Universities Power Engineering Conference. Tainan, China: IEEE, 1999: 114-117.
  • 10Guan Zhicheng, Cui Guoshun. A study on the leakage current along the surface of polluted insulator[C]//Proceedfings of the 4th International Conference on Properties And Applications Of Dielectric Materials. Brisbane Australia: [s. n. ], 1994 : 495- 498.