摘要 分析了FYT涂膜类防水粘结材料的基本性质,测定了它的具体技术指标,通过室内剪切与拉拔试验,确定了FYT的最佳用量与最佳用量范围,研究了温度、界面粗糙度和水对FYT路用性能的影响,并与其他常用防水粘结材料进行了路用性能对比分析。分析结果表明:FYT-1^#最佳洒布量为1.4~1.5kg·m^-2,FYT-2%#的最佳洒布量为0.10~0.15kg·m^-2;FYT在25℃时的抗剪强度与抗拉强度是60℃时的7~8倍;当遇水浸泡后,FYT抗剪强度损失3.0%,拉拔强度损失7.5%;FYT与同步碎石粘结性能相差不大,而与其他防水粘结材料相比,其抗剪强度与拉拔强度均高出3~4倍。可见,FYT具有优良的路用性能。 The basic properties of FYT waterproof were analyzed. Its specific technical indices were measured. Its optimum amount and optimum dosage range were determined by shear test and pullout test in laboratory. The influences of temperature, interracial roughness and water on the pavement performance of FYT waterproof were studied systematically. Comparison test analysis for FYT waterproof and the others used in common were carried out. Analysis result shows that optimum spreading volume for FYT-1^# is 1.4-1.5 kg · m^-2 , and that for FYT-2^# is 0. 1040.15 kg · m^-2. The shear strength and tensile strength of FYT at 25 ℃ is 7-8 times of that at 60 ℃. The losses of shear strength and tensile strength of FYT are respectively 3.0% and 7.5 % after soaking in water. Comparing with other waterproofs, except for synchronous crushed stone, its shear strength and tensile strength are 3-4 times of that of the others. Obviously, FYT has good pavement performance. 2 tabs, 14 figs, 11 refs.
出处 《交通运输工程学报》 EI CSCD 北大核心 2009年第3期34-38,共5页 Journal of Traffic and Transportation Engineering
基金 国家西部交通建设科技项目(200531881213)
关键词 路面材料 FYT 路用性能 室内试验 对比分析 pavement material FYT pavement performance laboratory test comparative analysis
  • 相关文献

参考文献10

二级参考文献53

共引文献174

同被引文献32

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部