摘要 Owing to its low cost and good transparency,highly purified water is widely used as a medium in large water Cerenkov detector experiments. The water circulation and purification system is usually needed to keep the water in good quality. In this work,a practical circulation model is built to describe the variation of the water resistivity in the circulation process and compared with the data obtained from a prototype experiment. The successful test of the model makes it useful in the future design and optimization of the circulation/purification system. Owing to its low cost and good transparency,highly purified water is widely used as a medium in large water Cerenkov detector experiments. The water circulation and purification system is usually needed to keep the water in good quality. In this work,a practical circulation model is built to describe the variation of the water resistivity in the circulation process and compared with the data obtained from a prototype experiment. The successful test of the model makes it useful in the future design and optimization of the circulation/purification system.
出处 《Chinese Physics C》 SCIE CAS CSCD 2009年第7期567-571,共5页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China (10535050)
关键词 water Cerenkov detector mixed-bed RESISTIVITY CIRCULATION water Cerenkov detector, mixed-bed, resistivity, circulation