期刊文献+

超声波键合能量引导微结构PMMA基片的制作(英文) 被引量:2

Fabrication of micro energy director on polymethyl methacrylate substrate for micro ultrasonic bonding
下载PDF
导出
摘要 为了用超声波键合的方法实现微流控芯片的封装,采用选择性键合方式在聚甲基丙烯酸甲酯(PMMA)基片的微沟道两侧设计、制作了能量引导微结构,用热压法在同一PMMA基片上一次成形了凸起的能量引导微结构和凹陷的微沟道。用套刻和湿法腐蚀的方法制作了复合一体化硅模具。通过正交实验,确定了优化后的热压工艺参数。实验结果表明,由于同时存在凹、凸微结构,因此优化后的热压成形温度比传统的热压凹陷结构的成形温度提高15 ~20 ℃,在温度为140 ℃、保压时间为300 s、压力为1 .65MPa的实验条件下,微结构的复制精度达到了99 %。 In order to use a micro ultrasonic bonding method to package polymer microfluidic auxiliary microstructure named micro energy director is designed and fabricated on two sides chips, an of the microchannel by a selective bonding method in this paper. A hot embossing method is adopted to fabri cate this newly designed Polymethyl Methacrylate(PMMA) substrate containing both convex micro energy directors and concave microchannels,then a complex silicon mold is designed and fabricated by the multi-photolithography and wet etching. By the Taguchi method, the optimized parameters for hot embossing are obtained. Experimental results show that the optimized embossing temperature is 15-- 20 ℃ higher than that of the simply replicate concave microstructure, since concave and convex micro structures are formed simultaneously. With the optimized parameters in an embossing temperature of 140 ℃, holding time of 300 s, and an embossing pressure of 1.65 MPa, the accuracy of replication can be up to 99%.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2009年第6期1373-1378,共6页 Optics and Precision Engineering
基金 Supported by the Programfor NewCentury Excellent Talents in University (NCET-06-0279) of Ministryof Education of China the National Natural Science Foundation of China (Grant No.50775024)
关键词 聚甲基丙烯酸甲酯基片 能量引导微结构 微超声键合 热压 Polymethyl Methacrylate(PMMA) substrate micro energy director micro ultrasonic bonding hot embossing
  • 相关文献

参考文献2

二级参考文献10

  • 1罗怡,王晓东,杨帆,刘冲.变温蠕变实验的COP微流控芯片热压制备[J].光学精密工程,2007,15(7):1090-1095. 被引量:7
  • 2薛伟,王晶,崔天宏.基于MEMS微加工技术的高灵敏度隧道传感器的研究(英文)[J].光学精密工程,2004,12(5):491-503. 被引量:8
  • 3[1]WANG H Y,FOOTE R S,JACOBSON S C,et al..Low temperature bonding for microfabrication of chemical analysis devices[J].Sensors and Actuators B:Chemical,1997,45(3):199-207.
  • 4[2]BURNS M A,JOHNSON B N,BRAHMASANDRA S N,et al..An integrated nanoliter DNA analysis device[J].Science,1998,5388(282):484-487.
  • 5[4]GEORGE W,WOODDRUFF III.Microfluidic channels in Polymethylmechacrylate by optimizing aluminum adhesion[C].22nd Annual Microelectronic Engineering Confefence,2004:110-113.
  • 6[5]SHEN X J,PAN L W,LIN L.Microplastic embossing process:experimental and theoretical characterizations[J].Sensors and Actuators A:Physical,2002(97/98):428-433.
  • 7[6]GERLACH A,KNEBEL G,GUBER A E,et al..Microfabrication of single-use plastic microfluidic devices for high-throughput screening and DNA analysis[J].Microsystem Technologies,2002,7(5/6):265-268.
  • 8[7]CHEN Z F,GAOY H,LIN J M,et al..Vacuum-assisted thermal bonding of plastic capillary electrophoresis microchip imprinted with stainless steel template[J].Journal of Chromatography A,2004,1038:239-245.
  • 9[9]LEI K F,LI W J,YAM Y.Effects of contact-stress on hot-embossed PMMA microchannel wall profile[J].Microsystem Technologies,2005,11:353-357.
  • 10[10]SCHEER H C,SCHULA H.A contribution To the flow behaviour of thin polymer films during hot embossing lithography[J].Microelectronic Engineering,2001,56:311-332.

共引文献18

同被引文献18

  • 1罗怡,王晓东,杨帆,刘冲.变温蠕变实验的COP微流控芯片热压制备[J].光学精密工程,2007,15(7):1090-1095. 被引量:7
  • 2陈晓平,王耘,胡树根,宋小文.基于流动模拟技木的注塑成型工艺参数优化[J].机械设计与制造,2005(2):68-69. 被引量:22
  • 3LEE S J, LEE S Y. Micro total analysis system (mu-TAS) in biotechnology[J]. Applied Microbi- ology and Biotechnology, 2004,64 : 289- 299.
  • 4BOHM S, DILGER K, HESSELBACH J, et al.. Micro bonding with non-viscous adhesives [J]. Mi- crosystem. Technologies, 2006,12(7) :676-679.
  • 5LI J H, CHEN D, CHEN G. Low-temperature thermal bonding of PMMA microfluidic chips [J]. Analytical Letters ,2005,38(7) : 1127-1136.
  • 6USSING T, PETERSEN L V, NIELSEN C B, et al.. Micro laser welding of polymer microstruc- tures using low power laser diodes [J]. Internation- al Journal of Advanced Manufacturing Technolo- gy ,2007,33(1-2) : 198-20.
  • 7YUSSUF A A, SBARSKI I, HAYES J P, et al.. Microwave welding of polymeric-microfluidic divic- es [J]. Journal of Micromechanics and Microengi- neering, 2005,15 : 1692-1699.
  • 8TRUCKENMULLER R,AHRENS R,CHENG Y, et al.. An ultrasonic welding based process for building up new class of inert fluidic microsensors and actuators from polymers[J]. Sensors and Actu- ators ,2006,132(1) :385-392.
  • 9KIM J, JEONG B, CHIAO M. Ultrasonic bonding for MEMS sealing and packaging[J]. IEEE Trans- actions on Advanced Packaging, 2009,32 (2) : 461 - 467.
  • 10NG S H, WANG Z F, ROOIJ N F de. Microfluidic connectors by ultrasonic welding[J]. Microelectron- ic Engineering, 2009,86(4-6) : 1354- 1357.

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部