期刊文献+

Sysmex XE-2100血细胞分析仪定量分析外周血幼稚粒细胞性能评价 被引量:9

The evaluation of quantitative measurement of immature granulocyte in peripheral blood using Sysmex XE-2100 hematology analyzer
下载PDF
导出
摘要 目的评价Sysmex XE-2100血细胞分析仪定量分析外周血幼稚粒细胞(IG)的性能。方法选取202份XE-2100IG报警值>200的样本,分别采用XE-2100和镜检分析IG%,评价两者之间相关性,选取5份不同IG%水平的样本进行XE-2100批内精密度(重复性)评价,分别选取8份标本在4℃和室温进行样本稳定性评价。结果XE-2100分析IG%结果与镜检结果具有良好的相关性(γ=0.8382,P<0.001);5份不同IG%水平样本重复性的变异系数(CV)从4.93%到15.5%;XE-2100分析4℃和室温保存24小时内的样本结果稳定。结论XE-2100定量分析外周血幼稚粒细胞性能良好,基本满足临床实验室要求。 Objective To evaluate the performance of quantitative measurement of immature granulocyte (IG) in peripheral blood using Sysmex XE-2100 hematology analyzer. Methods 202 samples with IG alarm value 〉200 were selected to evaluate the correlation between XE-2100 count and manual morphology count, 5 samples at different levels were selected to evaluate within-run reproducibility for XE-2100 IG count, 8 specimens were selected to evaluate the sample stability at 4℃ and at room temperature. Results The correlativity analysis showed IG agreement between XE-2100 count and the manual morphology count (γ=0.8382, P〈0.001); The within-run reproducibility performed using fresh blood on 5 different level specimens showed a range from 4.93% to 15.5% CV, The percent of IG were stable at both room temperature and after refrigeration for 24 hours. Conclusions The performance of quantitative measurement of immature granulocyte in peripheral blood using Sysmex XE-2100 hematology is well, it can meet the requirements of clinical laboratories.
出处 《实验与检验医学》 CAS 2009年第3期214-216,共3页 Experimental and Laboratory Medicine
关键词 血细胞分析仪 幼稚粒细胞 Hematology analyzer Immature granulocyte
  • 相关文献

参考文献8

  • 1Fernandes B, Hamaguchi Y. Automated Enumeration of Immature Granulocytes[J]. Am J Clin Pathol, 2007,128(3):454-463.
  • 2王小林,王宇,吴永华.XE-2100全自动血液分析仪自动幼稚粒细胞计数与显微镜方法比较[J].现代检验医学杂志,2006,21(6):62-63. 被引量:10
  • 3Fujimoto H, Sakata T, Hamaguchi Y, et al. Flow cytometric method for enumeration and classification of reactive immature granulocyte populations[J]. Cytometry. 2000,42(6):371-378.
  • 4凌励,惠小阳,沈茜,周道银,秦琴.Sysmex XE-2100血细胞分析仪在外周血干细胞临床检测中的功能评价[J].中华检验医学杂志,2003,26(11):697-698. 被引量:5
  • 5Ansari-Lori MA, Kidder TS, Borowitz MJ. Immature granulocyte measurement using the Sysmex XE-2100: relationship to infection and sepsis[J]. Am J Clin Pathol, 2003,120(5):795-799.
  • 6Nigro KG, O'Riordan M, Molloy E J, et al. Performance of an automated immature granulocyte count as a predictor of neonatal sepsis [J]. Am J Clin Pathol, 2005323(4):618-624.
  • 7朱晓辉,马洪玉,朱忠勇.应用血液学分析仪后显微镜复检标准刍议[J].中国实验诊断学,2006,10(3):296-298. 被引量:18
  • 8Barnes PW, Mcfadden SL, Machin SJ, et al. The International Consensus Group for Hematology Review: suggested criteria for action following automated CBC and WBC differential analysis [J]. Lab Hematol, 2005,11(2):83-90.

二级参考文献10

  • 1戴泽宁,金红,谢鑫友.血细胞分析仪应用中镜检标本筛选条件的探讨[J].检验医学,2004,19(4):366-367. 被引量:22
  • 2孙芾,王厚芳,于俊峰,穆煜,柳杰,杜振波.血细胞显微镜复检标准的制定及临床应用[J].中华检验医学杂志,2005,28(2):155-157. 被引量:128
  • 3马洪玉,朱忠勇.遗传性中性粒细胞过氧化物酶缺乏[J].国外医学(临床生物化学与检验学分册),2005,26(4):255-255. 被引量:4
  • 4韩忠朝 主编.造血干细胞理论与移植技术:第1版[M].河南:河南科技大学出版社,2001.210-214.
  • 5Ryan DH.Examination of the Blood.In:Beutler E,Lichtman MA,Coller BS,eds.Williams Hematology[M].6^th ed.New York,McGraw-Hill,2001:11.
  • 6Uptmore C,Connell B,Hart D.Comparison of the Sysmex XE-2100to the Abbott Cell-Dyn 4000 automated hematology analyzer[J].Sysmex Journal International,2001,11:22.
  • 7Anne Stien-Martin E,Lotspeich-Steininger C A,Koepke J A Clinical Hematology Principles,Procedures,Correlations[M].2^nd ed.Pheladelphia.Lippincott,1998,543-544.
  • 8Barnes P W,McFadden S L,Machin S J,et al.The international consensus group for hematology review:Suggested criteria for action following automated CBC and WBC differential analysis[J].Lab Hematol,2005,11:83.
  • 9Th Weiland,H Kalkman,H Heihn.Evaluation of the automated immature granulocyte count (IG) on sysmex XE-2100 automated haematology analyze vs visual microscopy (NCCLSH 20-A)[J].Sysmex Journal International,2002 ; 12 (2):
  • 10朱晓辉,何菊英,朱忠勇.应用血液分析仪后复查血片的内容和方法及程序[J].中华检验医学杂志,2003,26(12):785-787. 被引量:164

共引文献28

同被引文献44

引证文献9

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;