期刊文献+

固化光源对牙本质粘结强度的影响 被引量:6

Effect of Light Source on the Microtensile Bond Strength of Dentin
下载PDF
导出
摘要 目的:研究两种固化光源对牙本质粘结的微拉伸强度的影响。方法:选取因正畸需要拔除的前磨牙20颗,随机分成4组。去除面釉质,暴露平的牙本质表面,分别使用卤素光固化灯和发光二极管光固化灯固化粘结剂和复合树脂,形成3mm高的树脂冠:A组:卤素光固化灯固化粘结剂20s,卤素光固化灯固化树脂40s;B组:卤素光固化灯固化粘结剂20s,发光二极管光固化灯固化树脂30s;C组:发光二极管光固化灯固化粘结剂20s,发光二极管光固化灯固化树脂30s;D组:发光二极管光固化灯固化粘结剂20s,卤素光固化灯固化树脂40s。所有实验牙置于(37±1)℃的生理盐水中24h后,用硬组织切片机将其切成粘结面积约1.0mm×1.0mm的条形试件,用以测试牙本质微拉伸粘结强度。在扫描电镜下观察样本的断裂界面。结果:固化粘结剂的光源对牙本质微拉伸粘结强度的影响有显著的统计学意义(P<0.05)。4组中微拉伸粘结强度最大值为(29.55±4.39)MPa,出现在C组。扫描电镜下观察测试样本的断裂多数为粘结界面破坏。结论:固化光源对牙本质粘结的微拉伸强度存在影响,牙本质的粘结强度主要与固化粘结剂的光源有关。本实验显示使用发光二极管光固化灯固化粘结剂20s,发光二极管光固化灯固化树脂30s时牙本质的粘结强度最好。 Objective: To compare the effect of halogen dental curing light and light - emitting diode(LED) curing light on the microtensile bond strength of dentin. Methods: Twenty extracted human premolars were randomly divided into four groups o Resin crowns with 3ram high were built up on flat superficial dentin surface exposed after removing the occlusal enamel. The orthodontic adhesive and composite resin were polymerized using halogen dental curing light (QTH) and light - emitting diode(LED) curing light respectively: Group A, QTH curing for 20s for adhesive and 40s for the composite res- in; Group B, the adhesive cured with QTH for 20s, the composite resin cured with LED for 30s ; GroupC, LED curing for 20s for adhesive and 30s for the composite resin, Group D, the adhesive cured with LED for 20s ,the composite resin cured with QTH for 40s. After 24 hours'storage in water,all teeth were sectioned to obtain bar- shaped specimens with bonded surface area about 1.0mm × 1. 0mm. Dentin mierotensile bond strengths were measured~ All the fractured surfaces were observed under scanning electron microscope (SEM). Results: The results showed that the light source curing for adhesive affected significantly on microtensile bond strength of dentin(P 〈0.05). The highest bond strength value was (29.55± 4. 39 ) MPa, which was found in group C. SEM observations of failure patterns presented that most of them exhibited interra- cial cohesive failure. Conclusion: Different light sources influence microtensile bond strength of dentin. Bond strength is more dependent on the light source used for adhesive than for curing resin. The mierotensile bond strength of dentin is the best when the adhesive is exposed to light -emitting diode(LED) for 20 seconds and the resin exposed to LED for 30 seconds.
出处 《口腔医学研究》 CAS CSCD 北大核心 2009年第3期319-321,共3页 Journal of Oral Science Research
关键词 固化光源 牙本质粘结 微拉伸强度 Curing light source Dentin bond Microtensile strength
  • 相关文献

参考文献6

  • 1于博,牛玉梅,李艳萍.固化光源对充填体与牙体密合度影响的实验研究[J].口腔医学研究,2008,24(4):414-416. 被引量:6
  • 2Nakabayashi N,Kojima K,Masuhara E.The promotion of adhesion by the Infiltration of monomers into tooth states[J].J Biomed Mat Res,1982,16:265-73.
  • 3Inokoshi S,Hosoda H,Harnirattisai C,et al.Interfacial structure between dentin and dentin bonding systems revealed using argon ion beam etching[J].Oper Dent,1993,18:8-16.
  • 4Alhadainy HA,Abdalla AI.2-year clinical evaluation of dentin bondingsystems[J].Am J Dent,1996,9:77-79.
  • 5Yoshiyama M,Carvaho R,Sano H,et al.Interfacial morphology and strength of bonds made to superfacial versus deep dentin[J].Am J Dent,1995,8(6):297-302.
  • 6Ilie N,Felten K,Trixner K,et al.Shrinkage behavior of a resin-based composite irradiated with modern curing units[J].Dent Mater,2005,21(5):483-489.

二级参考文献8

共引文献5

同被引文献57

  • 1姬亚昆,凌均棨,陈罕,刘丽敏.卤素和LED光固化灯照射复合树脂的机械强度比较[J].实用口腔医学杂志,2006,22(2):227-229. 被引量:13
  • 2谭彦妮,刘咏,向其军.牙科光固化复合树脂材料的性能与展望[J].粉末冶金材料科学与工程,2007,12(3):139-145. 被引量:14
  • 3韩宁,侯本祥,徐爱凤.连续波热牙胶垂直充填术根尖微渗漏的研究[J].北京口腔医学,2007,15(4):223-224. 被引量:11
  • 4陈治清.口腔材料学[M].北京:人民卫生出版社,2008.
  • 5Theunis G Oberholzer, Ignatius C. Du Preez, M. Kidd. Effect of LED curing on the mieroleakage,shearbond strength and surface hardness of a resin--based composite restoration [J].Biomaterials, 2005, 26 : 3981-3986.
  • 6Amaral CM, Peris AR, Ambrosano GM, Swift EJ Jr, Pimenta LA. The effect of light--curing source and mode on microtensile bond strength to bovine dentin[J]. J Adhes Dent, 2006, 8 : 41-45.
  • 7Alhadainy HA, Abdalla AI. 2- year clinical evaluation of dentin bonding systems [J]. Am J Dent, 1996, 9 : 77-79.
  • 8Kanca J. Effect of resin primer solvents and surface wetness on resin composite bond strength to dentin [J]. Am J Dent, 1992, 5 : 213-215.
  • 9Bouillaguet S. Biological risks of resin--based materials to the dentin--pulp comples [J]. Crit Rev Oral Biol Med, 2004, 15 (1) : 47-60.
  • 10Meyer GR, Ernst CP, Willershausen B. Decrease in power output of new light--emitting diode (LED) curing devices withincreasing distance to filling surface [J]. J Adhes Dent, 2002, 4(3) : 197-204.

引证文献6