经皮椎体成形术的实验研究进展 被引量:3

下载PDF
导出
作者 甘秀天
出处 《微创医学》 2009年第3期265-267,共3页 Journal of Minimally Invasive Medicine
  • 相关文献

参考文献20

  • 1Tohmeh AG, Mathis JM, Fenton DC, et al. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures[ J ]. Spine, 1999,4 ( 17 ) : 1772 - 1776.
  • 2杨群,黄河,陈赛.经皮椎体成形术的临床应用研究[J].中华临床医学杂志,2006,7(7):9-13. 被引量:9
  • 3Dean JR, Ison KT, Gishen P. The strengthening effect of percutaneous vertebroplasty[ J]. Clin Radiol,2000,S5(6) :471 -476.
  • 4Wilson DR, Myers ER, Mathis JM, et al. Effect of augmentation on the mechanics of vertebral wedge fractures[ J ]. Spine,2000,25 (2) : 158 - 165.
  • 5Belkoff SM, Mathis JM, Jasper LE, et al. The biomechanies of vertebroplasty. The effect of cement volume on mechanical behavior[J]. Spine,2001,26(14) :1537 - 1541.
  • 6孙炳卫,刘淑恒,张涛,张庆国.经皮椎体成形术中骨水泥有效注射量探讨[J].山东医药,2006,46(36):42-42. 被引量:5
  • 7Liebschner MA, Rosenberg WS, Keaveny TM. Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty[ J ]. Spine,2001,26(14) :1547 - 1554.
  • 8Molloy S, Mathis JM, Belkoff SM. The effect of vertebral body percent-age fill on mechanical behavior during percutaneous vertebroplasty[J]. Spine,2003,28(14) : 1549 - 1554.
  • 9Belkoff SM, Mathis JM, Fenton DC, et al. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture[J]. Spine,2001,26(2) :151 - 156.
  • 10Higgins KB,Harten RD,Langrana NA. Biomechanical effects of unipedicular vertebroplasty on intact vertebrae [ J ]. Spine, 2003,28 (14) :1540 - 1547.

二级参考文献31

  • 1杨惠林,Hansen AYuan,陈亮,陆俭,倪才方,唐天驷.椎体后凸成形术治疗老年骨质疏松脊柱压缩骨折[J].中华骨科杂志,2003,23(5):262-265. 被引量:281
  • 2刘丹,吴震东,黄宰宇,王勇,张磊,应志豪,王圣斌.经皮椎体成形术治疗骨质疏松性脊柱压缩骨折的难点及探讨[J].中国矫形外科杂志,2005,13(2):150-151. 被引量:34
  • 3[4]Barr JD,Barr MS,Lemley TJ,et al.Pereutaneous vertebroplasty for pain relief and spinal stabilization[J].Spine,2000,25 (8):923-928.
  • 4[5]Togawa D,Kovacic JJ,Bauer TW,et al.Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine:percutaneous vertebroplasty varsus kyphoplasty[J].Spine,2006,31 (1):E4-10.
  • 5[6]Togawa D,Bauer TW,Lieberman IH,et al.Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate[J].Spine,2003,28 (14):1521-1527.
  • 6[7]Verlaan JJ,Oner FC,Slootweg PJ,et al.Histologic changes after vertebroplasty[J].J Bone Joint Surg Am,2004,86-A (6):1230-1238.
  • 7[8]Larsson S,Bauer TW.Use of injectable calcium phosphate ce-ment for fracture fixation:a review[J].Clin Orthop Ralat Res,2002,(395):23-32.
  • 8[9]Balkoff SM,Maroney M,Fenten DC,et al.An in vitro biomechanicel evaluation of bone cements used in percutaneous vertebroplasty[J].Bone,1999,25 (2 Suppl):23S-26S.
  • 9[10]Tomita S,Molloy S,Jasper LE,et al.Biomechanical comparison of kypboplasty with different bone cements[J].Spine,2004,29 (11):1203-1207.
  • 10[11]Belkoff SM,Mathis JM,Erbo EM,et al.Biomechanical evaluation of a new bone cement for use in vertebroplasty[J].Spine,2000,25 (9):1061-1064.