期刊文献+

电吸附设备工作过程的研究 被引量:14

Study on performance of electrosorption equipment
下载PDF
导出
摘要 研究了电压、流量及重碳酸盐碱度对电吸附设备除盐的影响,同时对高碱度水的酸化吹脱作为预处理进行了研究。实验结果表明,电吸附设备的最佳工作电压为1.4 V,最佳工作流量为1.5 m3/h。在进水碱度为170~500 mg/L时,HCO3-的脱附率为64%~83%。研究还发现,酸化吹脱是高碱度水的有效预处理方法,避免了HCO3-在电极内的积累。 The influences of voltage, flow rate and bicarbonate alkalinity on electrosorption equipment were studied. Also, the effect of acidification-stripping as pretreatment for high alkalinity water was investigated. The results show that the optimum voltage of electro-sorb equipment is 1.4 V, optimum flow rate is 1.5 m^3/h. For specific eleetrosorption equipment at alkalinity in a range of 170 - 500 mg/L, the desorption rate of HCO/ is 64% - 83%. The study indicates that using acidification-stripping as pretreatment may avoid the accumulation of HCO3 inside the electrode.
出处 《环境工程学报》 CAS CSCD 北大核心 2009年第7期1307-1310,共4页 Chinese Journal of Environmental Engineering
关键词 电吸附技术 电压 流量 重碳酸盐 酸化吹脱 eleetrosorption technology voltage flow rate bicarbonate acidification-stripping
  • 相关文献

参考文献8

  • 1Soldatov V. S. , Sokolova V. I. , Medyak G. V. , et al. Binary ion exchange equilibria in systems containing NO3^- , Cl^- and SO4^2- on fibrous anion exchangers with tetraalkylammomium groups. Reactive & Functional Polymers, 2007, 67:1530 - 1539.
  • 2Mohammad A. S. , Hisham E. Developments in thermal desalination processes: Design, energy, and costing aspects. Desalination, 2007, 214: 227- 240.
  • 3Laura J. B. , Thomas W. J. , Andrea I. Desalination using electrodialysis as a function of voltage and salt concentration. Desalination, 2007, 205 : 38 - 46.
  • 4Goztilivez J. M. , Lora J. , Mendoza J. A. , et al. Modeling of a low-pressure reverse osmosis system with concentrate recirculation to obtain high recovery levels. Desalination, 2002, 144:341 - 345.
  • 5Helal A. M. , El-Nashar A. M. , Al-Katheeri E. , et al. Optimal design of hybrid RO/MSF desalination plants, Part I: Modeling and algorithms. Desalination, 2003, 154:43-66.
  • 6Khaled W., Raja B. A., Loubna F., et al. Brackish groundwater treatment by nanofiltration, reverse osmosis and electrodialysis in Tunisia: Performance and cost comparison. Desalination, 2007, 207:95 - 106.
  • 7孙晓慰,朱国富.电吸附水处理技术及设备[J].工业水处理,2002,22(8):1-3. 被引量:53
  • 8Bard A. J., Faulkner L. R. Electrochemical Methods:Fundamentals and Applications. New York: John Wiley & Sons, 2000. 583.