摘要 目的评价连续波多普勒超声心排血量监测仪(USCOM1A)和连续温度稀释心排血量监测仪(VIGILANCE1A)监测冠状动脉旁路移植术(CABG)后患者的心排血量(CO)和心排血指数(CI),检验USCOMIA监测CO、CI的准确性。方法利用USCOMIA和VIGILANCE1A双盲监测18例CABG后患者的CO、CI,并分析其相关性。结果USCOM1A和VIGILANCE1A监测的CO、CI相关性良好(γCO=0.785,P〈0.01;γCO=0.727,P〈0.01)。结论可用无创的USCOM1A取代有创的VIGILANCE1A测量CO。
出处 《中国危重病急救医学》 CAS CSCD 北大核心 2009年第6期367-368,共2页 Chinese Critical Care Medicine
  • 相关文献

参考文献7

  • 1Darmon PL,Hillel Z,Mogtader A,et al.Cardiac output by transesophageal echocardiographyusing continuous wave Doppler across the aortic valve.Anesthesiology,1994,80(4):796-805.
  • 2Quinones MA,Otto CM,Stoddard M,et al.Recommendations for quantification of Doppler echocardiography:a report from the Doppler quantification task force of the nomenclature and standards committee of the American society of echocardiography.J Am Soc Echocardiogr,2002,15(2):167-184.
  • 3Critchley LA,Peng ZY,Fok BS,et al.Testing the reliability of a new uhrasonic cardiac output monitor,the USCOM,by using aortic flowprobes in anesthetized dogs.Anesth Analg,2005,100(3):748 753.
  • 4van Lelyveld-Haas LE,van Zanten AR,Borm GF,et al.Clinical validation of the non-invasive cardiac output monitor USCOM-1A in critically ill patients.Eur J Anaesthesiol,2008,25(11):917-924.
  • 5Chand R,Mehta Y,Trehan N.Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery.J Cardiothorac Vasc Anesth,2006,20(3):315-319.
  • 6Wong LS,Yong BH,Young KK,et al.Comparison of the USCOM ultrasonnd cardiac output monitor with pulmonary artery catheter thermodilntion in patients undergoing liver transplantation.Liver Trunspl,2008,14(7):1038-1043.
  • 7Tan HL,Pinder M,Parsons R,et al.Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit.Br J Anaesth,2005,94 (3):287-291.

同被引文献94

  • 1陈俊,赵劭懂,李军,葛许华,王晓榕,缪红军,江涛,喻文亮.无创心输出量监测(USCOM)在危重病患儿中的应用价值[J].医学信息(医学与计算机应用),2014,0(36):149-149. 被引量:2
  • 2金蓉,姬凤英,王众,李力,黄小元,焦彤.4种超声技术综合诊断下肢深静脉血栓形成[J].中国危重病急救医学,2006,18(2):120-120. 被引量:4
  • 3Brandstrup B, Tφnnesen H, Beier-Holgersen R, et al. Effects of intravenous fluid restriction on postoperative complications: comparison of two perioperative fluid regimens:a randomized assessor-blinded multicenter trial. Ann Surg,2003,238: 641-648.
  • 4Upadya A, Tilluckdharry L, Muralidharan V, et al. Fluid balance and weaning outcomes. Intensive Care Med, 2005,31:1643-1647.
  • 5Michard F,Teboul JL. Predicting fluid responsiveness in ICU patients :a critical analysis of the evidence. Chest, 2002,121:2000-2008.
  • 6Reuter DA, Felbinger TW, Schmidt C, et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med, 2002,28:392-398.
  • 7Biais M,Nouette-Gaulain K,Cottenceau V,et al. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth, 2008,101:761-768.
  • 8Caille V, Jabot J, Belliard G, et al. Hemodynamic effects of passive leg raising:an echocardiographic study in patients with shock. Intensive Care Med, 2008,34:1239-1245.
  • 9Lamia B, Ochagavia A, Monnet X, et al. Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med,2007,33:1125-1132.
  • 10Monnet X, Rienzo M, Osman D, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med, 2006,34:1402-1407.

引证文献9

二级引证文献117

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部