摘要 目的:用高效液相色谱法测定注射用肌苷的含量。方法:采用Kromasil C18柱(5μm 4.6mm×250mm),以甲醇-水(10:90)作流动相,在248nm紫外波长检测。结果:肌苷在4.23-63.48μg/ml范围内有良好的线性关系(r=0.9999)。低、中、高3个浓度的平均回收率(n=2)分别为101.4%、101.8%、101.1%,RSD为0.46%。结论:该法简便、快速、准确,可作为测定注射用肌苷中肌苷的含量。 Objective A high--performance liquid chromatography (HPLC) was established for the determination of inosine contents in injection. Methods Impurity in the inosine injection could be separated on Kromasil C18 colnmn (5μm 4. 6mm × 250mm) using methanol--water (10:90) as mobile phase and UV detector at 248nm. Results The linear range was 4.23-63. 48μg/ml(r=0. 9999). Average recovery in the lower, moderate and higher inosine concentration groups was respectively 101. 4 %, 101.8 % and 101.1% (n= 2) with RSD of 0.46 %. Conclusion The method is simple, rapid and accurate.
作者 石保龙
出处 《医学信息(下旬刊)》 2009年第6期244-244,共1页 Medical information
关键词 注射用肌苷 高效液相色谱法 含量测定 Inosine injection HPLC Coneentration determination